Applied potential tomography for non-invasive temperature mapping in hyperthermia. 1987

H Griffiths, and A Ahmed

In the field of hyperthermia for cancer treatment, much effort is being put into the development of non-invasive temperature monitoring so that the trauma of implanting thermocouple or thermistor probes in the patient can be avoided. Preliminary studies investigating the use of applied potential tomography (APT) for this purpose have been reported. APT has the advantages over other tomographic methods that the instrumentation is inexpensive, transportable, and could easily be accommodated in a hyperthermia treatment environment. Moreover, the temperature coefficient of electrical conductivity is large (2% degrees C-1) compared, for example, with the corresponding quantity in CT, the x-ray attenuation coefficient, which changes by only 0.04% degrees C-1. In our experimental system, 16 electrodes were fixed around a cylindrical block of agar simulating a human thigh. The system was driven with 5 mA at 50 kHz. The agar was heated using the 13.56 MHz capacitive system currently in clinical use in this hospital. By relating data sets recorded at different times during heating to a set recorded before heating, images of the temperature change in the agar with time were computed and are presented. The experiment was then repeated in vivo on the thigh of a volunteer.

UI MeSH Term Description Entries
D006979 Hyperthermia, Induced Abnormally high temperature intentionally induced in living things regionally or whole body. It is most often induced by radiation (heat waves, infra-red), ultrasound, or drugs. Fever Therapy,Hyperthermia, Local,Hyperthermia, Therapeutic,Thermotherapy,Induced Hyperthermia,Therapeutic Hyperthermia,Therapy, Fever,Local Hyperthermia
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008961 Models, Structural A representation, generally small in scale, to show the structure, construction, or appearance of something. (From Random House Unabridged Dictionary, 2d ed) Model, Structural,Structural Model,Structural Models
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D001831 Body Temperature The measure of the level of heat of a human or animal. Organ Temperature,Body Temperatures,Organ Temperatures,Temperature, Body,Temperature, Organ,Temperatures, Body,Temperatures, Organ
D004553 Electric Conductivity The ability of a substrate to allow the passage of ELECTRONS. Electrical Conductivity,Conductivity, Electric,Conductivity, Electrical
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000362 Agar A complex sulfated polymer of galactose units, extracted from Gelidium cartilagineum, Gracilaria confervoides, and related red algae. It is used as a gel in the preparation of solid culture media for microorganisms, as a bulk laxative, in making emulsions, and as a supporting medium for immunodiffusion and immunoelectrophoresis.
D012815 Signal Processing, Computer-Assisted Computer-assisted processing of electric, ultrasonic, or electronic signals to interpret function and activity. Digital Signal Processing,Signal Interpretation, Computer-Assisted,Signal Processing, Digital,Computer-Assisted Signal Interpretation,Computer-Assisted Signal Interpretations,Computer-Assisted Signal Processing,Interpretation, Computer-Assisted Signal,Interpretations, Computer-Assisted Signal,Signal Interpretation, Computer Assisted,Signal Interpretations, Computer-Assisted,Signal Processing, Computer Assisted
D013848 Thigh The superior part of the lower extremity between the HIP and the KNEE. Thighs

Related Publications

H Griffiths, and A Ahmed
January 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics,
H Griffiths, and A Ahmed
January 1992, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering,
H Griffiths, and A Ahmed
August 1989, Journal of the British Interplanetary Society,
H Griffiths, and A Ahmed
January 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group,
H Griffiths, and A Ahmed
January 1991, Acta radiologica (Stockholm, Sweden : 1987),
H Griffiths, and A Ahmed
January 1993, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group,
H Griffiths, and A Ahmed
January 2016, Expert review of anticancer therapy,