[Stroke volume, central venous oxygen saturation and blood temperature as control parameters of frequency-adapted pacemaker stimulation]. 1987

K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein

In order to compare various physiological parameters under identical conditions and to evaluate the "optimal" combination of parameters for triggering a pacing system, a multisensor-catheter of 7 F size was developed. By this catheter placed in the right ventricular cavity, sinus rate (SR), mixed venous oxygen saturation (SO2), temperature (T) and stroke volume (SV) were continuously recorded in 7 volunteers. SR, T, SO2 and SV were analysed for their steady state relationships to workload (P) and for their dynamic characteristics during standardized exercise tests. During exercise the delay times of SR, SO2 and SV were less than 10 sec., whereas that of T was markedly longer ranging from 70 sec. at low exercise levels to 30 sec. at high levels (200 Watts). During recovery delay times of SR, SO2 and SV ranged from 5 to 10 sec., that of T ranged from 20 to 30 sec. The relationship of SR to the workload (0-200 W) performed was linear (r = 0.98), that of T was linear above 50 Watts (r = 0.92), that of SO2 followed an exponential function (r = 0.89). Initial changes of SV were independent (r = 0.02) of the extent of workload. The sensitivity (S = dV/dP) was calculated from the relationship of the parameters (V) measured to the level of exercise performed. SO2 was highly sensitive at the lower range of exercise (less than 75 W), T became constantly sensitive above 50 W, below 50 W the sensitivity of T was continuously decreasing. SR was constantly sensitive over the whole range of exercise (0-200 W), the initial change of SV was not sensitive to the extent of workload.

UI MeSH Term Description Entries
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D001831 Body Temperature The measure of the level of heat of a human or animal. Organ Temperature,Body Temperatures,Organ Temperatures,Temperature, Body,Temperature, Organ,Temperatures, Body,Temperatures, Organ
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D013318 Stroke Volume The amount of BLOOD pumped out of the HEART per beat, not to be confused with cardiac output (volume/time). It is calculated as the difference between the end-diastolic volume and the end-systolic volume. Ventricular Ejection Fraction,Ventricular End-Diastolic Volume,Ventricular End-Systolic Volume,Ejection Fraction, Ventricular,Ejection Fractions, Ventricular,End-Diastolic Volume, Ventricular,End-Diastolic Volumes, Ventricular,End-Systolic Volume, Ventricular,End-Systolic Volumes, Ventricular,Fraction, Ventricular Ejection,Fractions, Ventricular Ejection,Stroke Volumes,Ventricular Ejection Fractions,Ventricular End Diastolic Volume,Ventricular End Systolic Volume,Ventricular End-Diastolic Volumes,Ventricular End-Systolic Volumes,Volume, Stroke,Volume, Ventricular End-Diastolic,Volume, Ventricular End-Systolic,Volumes, Stroke,Volumes, Ventricular End-Diastolic,Volumes, Ventricular End-Systolic

Related Publications

K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
December 1988, Biomedizinische Technik. Biomedical engineering,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
April 1988, Zeitschrift fur Kardiologie,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
November 2005, Clinical and experimental pharmacology & physiology,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
September 1984, Pacing and clinical electrophysiology : PACE,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
June 1988, The Journal of trauma,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
June 1998, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
July 2006, Archives of surgery (Chicago, Ill. : 1960),
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
August 2015, Journal of critical care,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
December 1996, Journal of anesthesia,
K Stangl, and A Wirtzfeld, and G Göbl, and R Heinze, and M Laule, and K Hoekstein
December 2012, Critical care medicine,
Copied contents to your clipboard!