Drowsiness Detection System Based on PERCLOS and Facial Physiological Signal. 2022

Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
Department of Electrical Engineering, National Chung Hsing University, Taichung 40227, Taiwan.

Accidents caused by fatigue occur frequently, and numerous scholars have devoted tremendous efforts to investigate methods to reduce accidents caused by fatigued driving. Accordingly, the assessment of the spirit status of the driver through the eyes blinking frequency and the measurement of physiological signals have emerged as effective methods. In this study, a drowsiness detection system is proposed to combine the detection of LF/HF ratio from heart rate variability (HRV) of photoplethysmographic imaging (PPGI) and percentage of eyelid closure over the pupil over time (PERCLOS), and to utilize the advantages of both methods to improve the accuracy and robustness of drowsiness detection. The proposed algorithm performs three functions, including LF/HF ratio from HRV status judgment, eye state detection, and drowsiness judgment. In addition, this study utilized a near-infrared webcam to obtain a facial image to achieve non-contact measurement, alleviate the inconvenience of using a contact wearable device, and for use in a dark environment. Furthermore, we selected the appropriate RGB channel under different light sources to obtain LF/HF ratio from HRV of PPGI. The main drowsiness judgment basis of the proposed drowsiness detection system is the use of algorithm to obtain sympathetic/parasympathetic nervous balance index and percentage of eyelid closure. In the experiment, there are 10 awake samples and 30 sleepy samples. The sensitivity is 88.9%, the specificity is 93.5%, the positive predictive value is 80%, and the system accuracy is 92.5%. In addition, an electroencephalography signal was used as a contrast to validate the reliability of the proposed method.

UI MeSH Term Description Entries
D004569 Electroencephalography Recording of electric currents developed in the brain by means of electrodes applied to the scalp, to the surface of the brain, or placed within the substance of the brain. EEG,Electroencephalogram,Electroencephalograms
D005221 Fatigue The state of weariness following a period of exertion, mental or physical, characterized by a decreased capacity for work and reduced efficiency to respond to stimuli. Lassitude
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001334 Automobile Driving The effect of environmental or physiological factors on the driver and driving ability. Included are driving fatigue, and the effect of drugs, disease, and physical disabilities on driving. Automobile Drivings,Driving, Automobile,Drivings, Automobile
D012894 Sleep Stages Periods of sleep manifested by changes in EEG activity and certain behavioral correlates; they formerly included Stage 1: sleep onset, drowsy sleep; Stage 2: light sleep; Stages 3 and 4: delta sleep, light sleep, deep sleep, telencephalic sleep. In 2007, sleep stages were redefined by The American Academy of Sleep Medicine (AASM) as: N1-N2 (sleep onset - light sleep), N3 (SLOW-WAVE SLEEP), and REM SLEEP. N1-Sleep,N2-Sleep,NREM Stage 1,NREM Stage 2,N1 Sleep,N2 Sleep,Sleep Stage,Stage, Sleep,Stages, Sleep
D014851 Wakefulness A state in which there is an enhanced potential for sensitivity and an efficient responsiveness to external stimuli. Wakefulnesses
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
February 2022, Journal of safety research,
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
January 2023, Sleep advances : a journal of the Sleep Research Society,
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
January 2023, Sensors (Basel, Switzerland),
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
January 2022, Journal of medical signals and sensors,
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
October 2023, Cognitive neurodynamics,
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
March 2023, Sensors (Basel, Switzerland),
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
October 2021, Sensors (Basel, Switzerland),
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
January 2022, Nature and science of sleep,
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
June 2022, Sensors (Basel, Switzerland),
Robert Chen-Hao Chang, and Chia-Yu Wang, and Wei-Ting Chen, and Cheng-Di Chiu
February 2009, European journal of applied physiology,
Copied contents to your clipboard!