Determination of myoglobin in human serum by high-performance liquid chromatography with chemiluminescence detection. 1987

V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii

A highly sensitive method for the determination of myoglobin in serum is described, based on high-performance size-exclusion chromatography with chemiluminescence detection. Serum proteins are separated according to their molecular masses on columns packed with TSK-SW gel and those containing haem are detected selectively by post-column chemiluminescence reaction with luminol using a conventional fluorimetric detector. The method is rapid (30 min) and sufficiently sensitive for the diagnosis of myocardial infarction. The minimum detectable myoglobin concentration is 10 ng/ml.

UI MeSH Term Description Entries
D007202 Indicators and Reagents Substances used for the detection, identification, analysis, etc. of chemical, biological, or pathologic processes or conditions. Indicators are substances that change in physical appearance, e.g., color, at or approaching the endpoint of a chemical titration, e.g., on the passage between acidity and alkalinity. Reagents are substances used for the detection or determination of another substance by chemical or microscopical means, especially analysis. Types of reagents are precipitants, solvents, oxidizers, reducers, fluxes, and colorimetric reagents. (From Grant & Hackh's Chemical Dictionary, 5th ed, p301, p499) Indicator,Reagent,Reagents,Indicators,Reagents and Indicators
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D008970 Molecular Weight The sum of the weight of all the atoms in a molecule. Molecular Weights,Weight, Molecular,Weights, Molecular
D009203 Myocardial Infarction NECROSIS of the MYOCARDIUM caused by an obstruction of the blood supply to the heart (CORONARY CIRCULATION). Cardiovascular Stroke,Heart Attack,Myocardial Infarct,Cardiovascular Strokes,Heart Attacks,Infarct, Myocardial,Infarction, Myocardial,Infarctions, Myocardial,Infarcts, Myocardial,Myocardial Infarctions,Myocardial Infarcts,Stroke, Cardiovascular,Strokes, Cardiovascular
D009211 Myoglobin A conjugated protein which is the oxygen-transporting pigment of muscle. It is made up of one globin polypeptide chain and one heme group.
D011863 Radioimmunoassay Classic quantitative assay for detection of antigen-antibody reactions using a radioactively labeled substance (radioligand) either directly or indirectly to measure the binding of the unlabeled substance to a specific antibody or other receptor system. Non-immunogenic substances (e.g., haptens) can be measured if coupled to larger carrier proteins (e.g., bovine gamma-globulin or human serum albumin) capable of inducing antibody formation. Radioimmunoassays
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
July 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
December 1984, Journal of chromatography,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
January 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
September 1999, Journal of chromatography. A,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
July 1995, Journal of chromatography. B, Biomedical applications,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
June 1992, Journal of chromatography,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
July 1995, Journal of chromatographic science,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
February 2006, Journal of chromatography. A,
V G Maltsev, and T M Zimina, and A B Khvatov, and B G Belenkii
November 2006, Biomedical chromatography : BMC,
Copied contents to your clipboard!