Label-free electrochemical immunosensor for picomolar detection of the cervical cancer biomarker MCM5. 2022

Ahmed Barhoum, and Robert J Forster
National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin, D09 V209, Ireland. Electronic address: ahmed.barhoum@dcu.ie.

An immunosensor for label-free electrochemical detection of MiniChromosome Maintenance Protein 5, MCM5, a protein overexpressed in cervical cancer, based on a gold electrode is reported. The electrode was first modified with a submonolayer (capture layer) of 11-mercaptoundecanoic acid (11-MUA) and then activated with N-(3-dimethylaminopropyl)-N-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to immobilize the capture antibody. The change in electrode surface properties (wettability) during the formation of the 11-MUA layers was determined using the static water contact angle (WCA). The binding of MCM5 antigens to the capture antibody was monitored by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using 5 mM [Fe(CN)6]3-/4- in 0.1 M LiClO4(aq) as an electroactive probe. AC Impedance was used to measure charge transfer resistance (Rct), which reflects impeded electron transfer when the antigen is bound to the antibody functionalized surface. After exposing the antibody-functionalized surface to MCM5 antigens, Rct increases linearly with the logarithmic value of MCM5 antigen concentration, with a linear dynamic range of 10-6 to 10-11 g/mL, a correlation coefficient of 0.99, and a detection limit of 2.9 pM (10-11 g/mL). This excellent sensitivity was achieved with simple preparation steps and minimal reagent consumption, without the need for complicated procedures such as enzymatic amplification, fluorescent labeling, or nanoparticle modification.

UI MeSH Term Description Entries
D007118 Immunoassay A technique using antibodies for identifying or quantifying a substance. Usually the substance being studied serves as antigen both in antibody production and in measurement of antibody by the test substance. Immunochromatographic Assay,Assay, Immunochromatographic,Assays, Immunochromatographic,Immunoassays,Immunochromatographic Assays
D002583 Uterine Cervical Neoplasms Tumors or cancer of the UTERINE CERVIX. Cancer of Cervix,Cancer of the Cervix,Cancer of the Uterine Cervix,Cervical Cancer,Cervical Neoplasms,Cervix Cancer,Cervix Neoplasms,Neoplasms, Cervical,Neoplasms, Cervix,Uterine Cervical Cancer,Cancer, Cervical,Cancer, Cervix,Cancer, Uterine Cervical,Cervical Cancer, Uterine,Cervical Cancers,Cervical Neoplasm,Cervical Neoplasm, Uterine,Cervix Neoplasm,Neoplasm, Cervix,Neoplasm, Uterine Cervical,Uterine Cervical Cancers,Uterine Cervical Neoplasm
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D005260 Female Females
D006046 Gold A yellow metallic element with the atomic symbol Au, atomic number 79, and atomic weight 197. It is used in jewelry, goldplating of other metals, as currency, and in dental restoration. Many of its clinical applications, such as ANTIRHEUMATIC AGENTS, are in the form of its salts.
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014408 Biomarkers, Tumor Molecular products metabolized and secreted by neoplastic tissue and characterized biochemically in cells or BODY FLUIDS. They are indicators of tumor stage and grade as well as useful for monitoring responses to treatment and predicting recurrence. Many chemical groups are represented including HORMONES; ANTIGENS; amino and NUCLEIC ACIDS; ENZYMES; POLYAMINES; and specific CELL MEMBRANE PROTEINS and LIPIDS. Biochemical Tumor Marker,Cancer Biomarker,Carcinogen Markers,Markers, Tumor,Metabolite Markers, Neoplasm,Tumor Biomarker,Tumor Marker,Tumor Markers, Biochemical,Tumor Markers, Biological,Biochemical Tumor Markers,Biological Tumor Marker,Biological Tumor Markers,Biomarkers, Cancer,Marker, Biochemical Tumor,Marker, Biologic Tumor,Marker, Biological Tumor,Marker, Neoplasm Metabolite,Marker, Tumor Metabolite,Markers, Biochemical Tumor,Markers, Biological Tumor,Markers, Neoplasm Metabolite,Markers, Tumor Metabolite,Metabolite Markers, Tumor,Neoplasm Metabolite Markers,Tumor Markers, Biologic,Tumor Metabolite Marker,Biologic Tumor Marker,Biologic Tumor Markers,Biomarker, Cancer,Biomarker, Tumor,Cancer Biomarkers,Marker, Tumor,Markers, Biologic Tumor,Markers, Carcinogen,Metabolite Marker, Neoplasm,Metabolite Marker, Tumor,Neoplasm Metabolite Marker,Tumor Biomarkers,Tumor Marker, Biochemical,Tumor Marker, Biologic,Tumor Marker, Biological,Tumor Markers,Tumor Metabolite Markers
D015374 Biosensing Techniques Any of a variety of procedures which use biomolecular probes to measure the presence or concentration of biological molecules, biological structures, microorganisms, etc., by translating a biochemical interaction at the probe surface into a quantifiable physical signal. Bioprobes,Biosensors,Electrodes, Enzyme,Biosensing Technics,Bioprobe,Biosensing Technic,Biosensing Technique,Biosensor,Electrode, Enzyme,Enzyme Electrode,Enzyme Electrodes,Technic, Biosensing,Technics, Biosensing,Technique, Biosensing,Techniques, Biosensing
D053768 Metal Nanoparticles Nanoparticles produced from metals whose uses include biosensors, optics, and catalysts. In biomedical applications the particles frequently involve the noble metals, especially gold and silver. Metal Nanocrystals,Metallic Nanocrystals,Metallic Nanoparticles,Metal Nanocrystal,Metal Nanoparticle,Metallic Nanocrystal,Metallic Nanoparticle,Nanocrystal, Metal,Nanocrystal, Metallic,Nanocrystals, Metal,Nanocrystals, Metallic,Nanoparticle, Metal,Nanoparticle, Metallic,Nanoparticles, Metal,Nanoparticles, Metallic
D055664 Electrochemical Techniques The utilization of an electrical current to measure, analyze, or alter chemicals or chemical reactions in solution, cells, or tissues. Electrochemical Technics,Electrochemical Technic,Electrochemical Technique,Technic, Electrochemical,Technics, Electrochemical,Technique, Electrochemical,Techniques, Electrochemical

Related Publications

Ahmed Barhoum, and Robert J Forster
April 2011, Biosensors & bioelectronics,
Ahmed Barhoum, and Robert J Forster
March 2022, Analytical and bioanalytical chemistry,
Ahmed Barhoum, and Robert J Forster
November 2021, Biosensors & bioelectronics,
Ahmed Barhoum, and Robert J Forster
January 2013, Biosensors & bioelectronics,
Ahmed Barhoum, and Robert J Forster
August 2023, Talanta,
Copied contents to your clipboard!