Development of a high energy resolution and wide dose rate range portable gamma-ray spectrometer. 2023

Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China; Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China.

In this paper, a portable gamma-ray spectrometer for real-time and in-situ gamma-ray detection applications is presented. By combining a quasi-hemispherical CdZnTe (CZT) semiconductor detector and a Geiger-Muller (GM) counter together, a wide dose rate range is achieved, ranging from 0.1 μSv/h to 100 mSv/h with a relative error of less than 10%. The GM counter is used to measure dose rate from 1 mSv/h to 100 mSv/h. With CZT, the spectrometer can provide a high energy resolution spectrum for nuclide identification and a high precision dose rate at low dose rates. The full width half maximum (FWHM) resolution is 2.2% at 662 keV below 70 μSv/h and is better than 3.3% at 3.8 mSv/h. The weight of the spectrometer is 3.2 kg for handheld and the runtime is up to 12 h without charging. For preliminary applications, the spectrometer was used to measure the gamma radiation around the Back-n white neutron beam line at China Spallation Neutron Source and around the steam generator in the nuclear power plant at Daya Bay Nuclear Power Station.

UI MeSH Term Description Entries
D009502 Neutrons Electrically neutral elementary particles found in all atomic nuclei except light hydrogen; the mass is equal to that of the proton and electron combined and they are unstable when isolated from the nucleus, undergoing beta decay. Slow, thermal, epithermal, and fast neutrons refer to the energy levels with which the neutrons are ejected from heavier nuclei during their decay. Neutron
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D005720 Gamma Rays Penetrating, high-energy electromagnetic radiation emitted from atomic nuclei during NUCLEAR DECAY. The range of wavelengths of emitted radiation is between 0.1 - 100 pm which overlaps the shorter, more energetic hard X-RAYS wavelengths. The distinction between gamma rays and X-rays is based on their radiation source. Gamma Wave,Gamma Radiation,Nuclear X-Rays,Radiation, Gamma,X-Rays, Nuclear,Gamma Radiations,Gamma Ray,Gamma Waves,Nuclear X Rays,Nuclear X-Ray,Ray, Gamma,Wave, Gamma,Waves, Gamma,X Rays, Nuclear,X-Ray, Nuclear
D013691 Tellurium An element that is a member of the chalcogen family. It has the atomic symbol Te, atomic number 52, and atomic weight 127.60. It has been used as a coloring agent and in the manufacture of electrical equipment. Exposure may cause nausea, vomiting, and CNS depression.

Related Publications

Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
January 2004, Radiation protection dosimetry,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
October 1968, Health physics,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
September 2012, The Review of scientific instruments,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
November 2023, Sensors (Basel, Switzerland),
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
December 2019, The Review of scientific instruments,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
September 2000, Health physics,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
August 2008, The Review of scientific instruments,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
April 2016, The Review of scientific instruments,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
June 1950, The Review of scientific instruments,
Yichao Wang, and Changqing Feng, and Maoyuan Zhao, and Chenyu Shan, and Feng Liu, and Qingxin Lei, and Ziheng Zhou, and Shubin Liu
November 2014, The Review of scientific instruments,
Copied contents to your clipboard!