[Fully automatic computer-analysis of electrocardiograms in clinical routine (author's transl)]. 1978

H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting

A fully automated Ecg recording and interpretation system (Hewlett Packard HP 5) consisting of a central computer and two peripheral units was evaluated during a four-month period. Ecgs were transmitted via public telephone lines, as was the report from central station to peripheral recording and print-out unit. Within a few seconds after recording and print-out unit. Within a few seconds after recording and transmission a preliminary report is available in printed format. The transmitted Ecgs are stored at the central computer and are being retrieved and evaluated manually there. Three cardiologists read the tracings and furnished final reports. 468 Ecgs were thus compared in our test time of 10 days for statistical evaluation with the following results: 1. 73.1% of all statements were read correctly by the computer. 2. There is a large range of diagnostic accuracy between 0% and 100%. 3. The evaluation of Ecg changed by cardiologists reflects the individual experience of the controllers regarding the Ecg statements as well as computer-dependent possibilities like modification etc. of Ecg. 4. As an example the diagnosis "myocardial infarction" is compared with other Ecg computer programs by means of a quality index calculated from sensitivity and specificity: HP 5 with 158.5 points reaches a similar level as the Pipberger program with 162.6 and the Bonner with 159.5 points. 5. Referring to false negative results this program is acceptable in all diagnostic groups with ca. 8%, except conduction defects with 17.7%. 6. Referring to false positive results the diagnostic groups myocardial infarction/ischemia and conduction defects are not satisfactory with 36.5% and 23.4%. 7. In all the tested system seems to be very useful in routine Ecg interpretation of bigger hospitals.

UI MeSH Term Description Entries
D002309 Cardiology The study of the heart, its physiology, and its functions. Angiology,Cardiovascular Disease Specialty,Vascular Medicine,Disease Specialty, Cardiovascular,Medicine, Vascular,Specialty, Cardiovascular Disease
D003629 Modems Equipment that sends digital information over telephone lines. The term Modem is a short form of the phrase modulator-demodulator. Dataphones,Dataphone,Modem
D003936 Diagnosis, Computer-Assisted Application of computer programs designed to assist the physician in solving a diagnostic problem. Computer-Assisted Diagnosis,Computer Assisted Diagnosis,Computer-Assisted Diagnoses,Diagnoses, Computer-Assisted,Diagnosis, Computer Assisted
D003951 Diagnostic Errors Incorrect or incomplete diagnoses following clinical or technical diagnostic procedures. Diagnostic Blind Spots,Errors, Diagnostic,Misdiagnosis,Blind Spot, Diagnostic,Blind Spots, Diagnostic,Diagnostic Blind Spot,Diagnostic Error,Error, Diagnostic,Misdiagnoses
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005188 False Negative Reactions Negative test results in subjects who possess the attribute for which the test is conducted. The labeling of diseased persons as healthy when screening in the detection of disease. (Last, A Dictionary of Epidemiology, 2d ed) False Negative Reaction,Reaction, False Negative,Reactions, False Negative
D005860 Germany, West The former Federal Republic of Germany which was reunified with the former German Democratic Republic in 1990. Federal Republic of Germany,Germany, Federal Republic of
D006331 Heart Diseases Pathological conditions involving the HEART including its structural and functional abnormalities. Cardiac Disorders,Heart Disorders,Cardiac Diseases,Cardiac Disease,Cardiac Disorder,Heart Disease,Heart Disorder
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
June 1974, Deutsche medizinische Wochenschrift (1946),
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
January 1964, American heart journal,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
June 1977, Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
December 1979, Nihon Jibiinkoka Gakkai kaiho,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
December 1980, Zhonghua xin xue guan bing za zhi,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
April 1967, Saishin igaku. Modern medicine,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
January 1974, Materia medica Polona. Polish journal of medicine and pharmacy,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
January 1977, Revue d'electroencephalographie et de neurophysiologie clinique,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
August 1978, Rinsho byori. The Japanese journal of clinical pathology,
H J Mengden, and H Just, and W Kaspar, and H Löllgen, and F Kersting
June 1973, Acta cardiologica,
Copied contents to your clipboard!