Margin of safety in positioning modern double-lumen endotracheal tubes. 1987

J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
Department of Anesthesia, University of California, San Diego, La Jolla 92093.

The authors have defined the margin of safety in positioning a double-lumen tube as the length of tracheobronchial tree over which it may be moved or positioned without obstructing a conducting airway. The purpose of this study was to measure the margin of safety in positioning three modern double-lumen tubes (Mallinkrodt [Broncho-Cath], Rusch [Endobronchial tubes], and Sheridan [Broncho-Trach]). The margin of safety in positioning a: 1) left-sided double-lumen tube (all manufacturers) is the length of the left mainstem bronchus minus the length from the proximal margin of the left cuff to left lumen tip; 2) Mallinkrodt right-sided double-lumen tube is the length of the right mainstem bronchus minus the length of the right cuff; and 3) Rusch right-sided double-lumen tube is the length of the right upper lobe ventilation slot minus the diameter of the right upper lobe. The length of the right and left mainstem bronchi were measured by in vivo fiberoptic bronchoscopy (n = 69), in fresh cadavers (n = 42), and in lung casts (n = 55), and the diameter of the right upper lobe bronchus was measured in lung casts (n = 55). The average +/- SD male left and right mainstem bronchial lengths were 49 +/- 8 and 19 +/- 6 mm, respectively, the average +/- SD female left and right mainstem bronchial lengths were 44 +/- 7 and 15 +/- 5 mm, respectively, the average right upper lobe bronchial diameter was 11 mm, the proximal left cuff to left lumen tip distance was 30 mm, the length of the Mallinkrodt right cuff was 10 mm, and the length of the Rusch right upper lobe ventilation slot was 15 mm. The average margin of safety in positioning left-sided double-lumen tubes ranged 16-19 mm for the different manufacturers. The average margin of safety in positioning Mallinkrodt right-sided double-lumen tubes was 8 mm, and the margin of safety in positioning Rusch right-sided double-lumen tubes ranged 1-4 mm, depending on French size. The authors concluded that left-sided double-lumen tubes are much preferable to right-sided double-lumen tubes because they have a much greater positioning margin of safety, and that proper confirmation of proper position of either a left- or right-sided double-lumen tube should be aided by fiberoptic bronchoscopy, because the absolute distances that constitute the margin of safety are extremely small.

UI MeSH Term Description Entries
D007442 Intubation, Intratracheal A procedure involving placement of a tube into the trachea through the mouth or nose in order to provide a patient with oxygen and anesthesia. Intubation, Endotracheal,Endotracheal Intubation,Endotracheal Intubations,Intratracheal Intubation,Intratracheal Intubations,Intubations, Endotracheal,Intubations, Intratracheal
D007839 Functional Laterality Behavioral manifestations of cerebral dominance in which there is preferential use and superior functioning of either the left or the right side, as in the preferred use of the right hand or right foot. Ambidexterity,Behavioral Laterality,Handedness,Laterality of Motor Control,Mirror Writing,Laterality, Behavioral,Laterality, Functional,Mirror Writings,Motor Control Laterality,Writing, Mirror,Writings, Mirror
D008297 Male Males
D001980 Bronchi The larger air passages of the lungs arising from the terminal bifurcation of the TRACHEA. They include the largest two primary bronchi which branch out into secondary bronchi, and tertiary bronchi which extend into BRONCHIOLES and PULMONARY ALVEOLI. Primary Bronchi,Primary Bronchus,Secondary Bronchi,Secondary Bronchus,Tertiary Bronchi,Tertiary Bronchus,Bronchi, Primary,Bronchi, Secondary,Bronchi, Tertiary,Bronchus,Bronchus, Primary,Bronchus, Secondary,Bronchus, Tertiary
D004869 Equipment Safety Freedom of equipment from actual or potential hazards. Device Safety,Hazards, Equipment,Medical Device Safety,Safety, Equipment,Device Safety, Medical,Safety, Medical Device,Equipment Hazard,Equipment Hazards,Hazard, Equipment,Safety, Device
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
July 1988, Anesthesiology,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
September 1991, Clinics in chest medicine,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
November 1992, Anaesthesia and intensive care,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
May 2012, Canadian journal of anaesthesia = Journal canadien d'anesthesie,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
August 1989, Journal of cardiothoracic anesthesia,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
November 1975, Anaesthesia and intensive care,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
February 1991, The Annals of thoracic surgery,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
January 1988, Anesthesiology,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
November 1998, Anesthesiology,
J L Benumof, and B L Partridge, and C Salvatierra, and J Keating
August 1981, Anaesthesia,
Copied contents to your clipboard!