Diastolic blood pressure as a determinant of Doppler left ventricular filling indexes in normotensive adolescents. 1987

W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
Hypertension Center, Veterans Administration Medical Center, Long Beach, California 90822.

Alterations in left ventricular filling can occur with aging and in patients with hypertension, ischemic heart disease, congestive and hypertrophic cardiomyopathy and congenital heart disease. This study examines the effects of blood pressure on left ventricular diastolic filling indexes measured by Doppler ultrasound technique in 47 young normotensive adolescents (mean age 13 years). Left ventricular filling was assessed by Doppler peak early and late diastolic transmitral flow velocities, early and late diastolic flow velocity integrals and early diastolic deceleration. Systolic blood pressure did not correlate with any of the Doppler filling indexes, although it was related to echocardiographic left ventricular mass (r = 0.44, p less than 0.005). Diastolic blood pressure did not correlate with left ventricular mass; however, it was inversely related to peak early diastolic flow velocity (r = -0.44, p less than 0.005), early diastolic flow velocity integral (r = -0.40, p less than 0.01) and early diastolic deceleration (r = -0.32, p less than 0.05). The ratio of late to early peak filling (A/E) was directly related to diastolic blood pressure (r = 0.48, p less than 0.001). Examination of electrocardiograms showed that there was a stronger correlation between A/E ratio and diastolic blood pressure (r = 0.63) in 22 subjects with bimodal P waves in lead V1 than in subjects with unimodal P waves (r = 0.45).(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D006973 Hypertension Persistently high systemic arterial BLOOD PRESSURE. Based on multiple readings (BLOOD PRESSURE DETERMINATION), hypertension is currently defined as when SYSTOLIC PRESSURE is consistently greater than 140 mm Hg or when DIASTOLIC PRESSURE is consistently 90 mm Hg or more. Blood Pressure, High,Blood Pressures, High,High Blood Pressure,High Blood Pressures
D008297 Male Males
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D002648 Child A person 6 to 12 years of age. An individual 2 to 5 years old is CHILD, PRESCHOOL. Children
D003971 Diastole Post-systolic relaxation of the HEART, especially the HEART VENTRICLES. Diastoles
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females

Related Publications

W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
May 1979, The Annals of thoracic surgery,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
January 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
March 1991, The American journal of cardiology,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
January 1988, Journal of electrocardiology,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
November 1995, American heart journal,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
April 1992, Journal of hypertension. Supplement : official journal of the International Society of Hypertension,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
June 1993, The American journal of cardiology,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
December 1994, International journal of cardiology,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
September 1991, The American journal of cardiology,
W F Graettinger, and M A Weber, and J M Gardin, and M L Knoll
October 2000, Journal of hypertension,
Copied contents to your clipboard!