Using pressure-driven flow systems to evaluate laser speckle contrast imaging. 2023

Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
The University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.

Microfluidic flow phantom studies are commonly used for characterizing the performance of laser speckle contrast imaging (LSCI) instruments. The selection of the flow control system is critical for the reliable generation of flow during testing. The majority of recent LSCI studies using microfluidics used syringe pumps for flow control. We quantified the uncertainty in flow generation for a syringe pump and a pressure-regulated flow system. We then assessed the performance of both LSCI and multi-exposure speckle imaging (MESI) using the pressure-regulated flow system across a range of flow speeds. The syringe pump and pressure-regulated flow systems were evaluated during stepped flow profile experiments in a microfluidic device using an inline flow sensor. The uncertainty associated with each flow system was calculated and used to determine the reliability for instrument testing. The pressure-regulated flow system was then used to characterize the relative performance of LSCI and MESI during stepped flow profile experiments while using the inline flow sensor as reference. The pressure-regulated flow system produced much more stable and reproducible flow outputs compared to the syringe pump. The expanded uncertainty for the syringe pump was 8 to higher than that of the pressure-regulated flow system across the tested flow speeds. Using the pressure-regulated flow system, MESI outperformed single-exposure LSCI at all flow speeds and closely mirrored the flow sensor measurements, with average errors of and , respectively. Pressure-regulated flow systems should be used instead of syringe pumps when assessing the performance of flow measurement techniques with microfluidic studies. MESI offers more accurate relative flow measurements than traditional LSCI across a wide range of flow speeds.

UI MeSH Term Description Entries
D012039 Regional Blood Flow The flow of BLOOD through or around an organ or region of the body. Blood Flow, Regional,Blood Flows, Regional,Flow, Regional Blood,Flows, Regional Blood,Regional Blood Flows
D003952 Diagnostic Imaging Any visual display of structural or functional patterns of organs or tissues for diagnostic evaluation. It includes measuring physiologic and metabolic responses to physical and chemical stimuli, as well as ultramicroscopy. Imaging, Diagnostic,Imaging, Medical,Medical Imaging
D000081982 Laser Speckle Contrast Imaging Two-dimensional imaging created from the quantification of the blurring of speckle (randomly varying intensity patterns of light seen after it is scattered through a medium) that occurs spatially or temporally. LSCI is used for measuring blood flow in tissues such as the retina, skin, and brain.
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D017078 Laser-Doppler Flowmetry A method of non-invasive, continuous measurement of MICROCIRCULATION. The technique is based on the values of the DOPPLER EFFECT of low-power laser light scattered randomly by static structures and moving tissue particulates. Doppler-Laser Flowmetry,Flowmetry, Laser-Doppler,Laser-Doppler Velocimetry,Velocimetry, Laser-Doppler,Doppler Laser Flowmetry,Flowmetry, Doppler-Laser,Flowmetry, Laser Doppler,Laser Doppler Flowmetry,Laser Doppler Velocimetry,Velocimetry, Laser Doppler
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
January 2010, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
February 2012, Annals of biomedical engineering,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
January 2010, Journal of biomedical optics,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
January 2017, European journal of pediatric surgery reports,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
January 2013, Biomedical optics express,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
January 2014, Methods in molecular biology (Clifton, N.J.),
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
November 2018, Optics letters,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
September 2013, Journal of biomedical optics,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
May 2020, Journal of biomedical optics,
Colin T Sullender, and Adam Santorelli, and Lisa M Richards, and Pawan K Mannava, and Christopher Smith, and Andrew K Dunn
January 2022, Cardiology journal,
Copied contents to your clipboard!