Precision of measurements of right and left ventricular volume by cine computed tomography. 1986

S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus

Precise determination of left and right ventricular stroke volumes is limited with conventional imaging techniques. We determined whether right and left ventricular stroke volumes could be precisely measured with cine computed tomography (CT). Cine CT enables simultaneous imaging of the right and left ventricles at an 8 mm slice thickness with a maximal scanning rate of 17 frames/sec (50 msec acquisition intervals). In eight dogs, true right ventricular and left ventricular stroke volumes were determined by dividing thermodilution cardiac output by heart rate and/or with the use of an aortic electromagnetic flow probe implanted over a long term. After at least 5 sec of suspended respiration, cine CT images were acquired during central venous injection of a nonionic contrast agent. Multiple perturbations in stroke volume were induced in each dog by the administration of dobutamine, sodium pentobarbital, or sodium nitroprusside or by coronary artery occlusion. Right and left ventricular stroke volumes were obtained by Simpson's reconstruction of end-diastolic and end-systolic short-axis tomograms from apex to base. The cine CT left ventricular stroke volume (range 11 to 45 ml) correlated highly with the true left ventricular stroke volume (r = .99, slope = 1.01, y intercept = -0.2 ml, SEE = 1.5 ml, n = 25). The cine CT right ventricular stroke volume (range 11 to 34 ml) also correlated highly with the true right ventricular stroke volume (r = .98, slope = 0.9, y intercept = 2.2 ml, SEE = 1.7 ml, n = 15). In 12 studies, the mean difference between nearly simultaneous right and left ventricular stroke volumes by cine CT was 1.1 ml (range 0.1 to 3.2 ml). Calculation of right and left ventricular stroke volumes from data from cine CT were highly reproducible. Intraobserver variability in measurements of right ventricular stroke volume (r = 1.0, slope = 0.99, y intercept = 0.19 ml) and left ventricular stroke volume (r = 1.0, slope = 1.02, y intercept = -0.21 ml) was minimal. Interobserver variability in measurements of right ventricular stroke volume (r = .98, slope = 0.90, y intercept = 1.66 ml) and left ventricular stroke volume (r = .99, slope = 0.97, y intercept = -0.02 ml) was likewise minimal. Thus, precise and highly reproducible measurements of right and left ventricular stroke volumes can be obtained with cine CT.

UI MeSH Term Description Entries
D002933 Cineradiography Motion picture study of successive images appearing on a fluoroscopic screen. Cinefluorography,Radiocinematography,Cinefluorographies,Cineradiographies,Radiocinematographies
D003287 Contrast Media Substances used to allow enhanced visualization of tissues. Radiopaque Media,Contrast Agent,Contrast Agents,Contrast Material,Contrast Materials,Radiocontrast Agent,Radiocontrast Agents,Radiocontrast Media,Agent, Contrast,Agent, Radiocontrast,Agents, Contrast,Agents, Radiocontrast,Material, Contrast,Materials, Contrast,Media, Contrast,Media, Radiocontrast,Media, Radiopaque
D004285 Dogs The domestic dog, Canis familiaris, comprising about 400 breeds, of the carnivore family CANIDAE. They are worldwide in distribution and live in association with people. (Walker's Mammals of the World, 5th ed, p1065) Canis familiaris,Dog
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006352 Heart Ventricles The lower right and left chambers of the heart. The right ventricle pumps venous BLOOD into the LUNGS and the left ventricle pumps oxygenated blood into the systemic arterial circulation. Cardiac Ventricle,Cardiac Ventricles,Heart Ventricle,Left Ventricle,Right Ventricle,Left Ventricles,Right Ventricles,Ventricle, Cardiac,Ventricle, Heart,Ventricle, Left,Ventricle, Right,Ventricles, Cardiac,Ventricles, Heart,Ventricles, Left,Ventricles, Right
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D013318 Stroke Volume The amount of BLOOD pumped out of the HEART per beat, not to be confused with cardiac output (volume/time). It is calculated as the difference between the end-diastolic volume and the end-systolic volume. Ventricular Ejection Fraction,Ventricular End-Diastolic Volume,Ventricular End-Systolic Volume,Ejection Fraction, Ventricular,Ejection Fractions, Ventricular,End-Diastolic Volume, Ventricular,End-Diastolic Volumes, Ventricular,End-Systolic Volume, Ventricular,End-Systolic Volumes, Ventricular,Fraction, Ventricular Ejection,Fractions, Ventricular Ejection,Stroke Volumes,Ventricular Ejection Fractions,Ventricular End Diastolic Volume,Ventricular End Systolic Volume,Ventricular End-Diastolic Volumes,Ventricular End-Systolic Volumes,Volume, Stroke,Volume, Ventricular End-Diastolic,Volume, Ventricular End-Systolic,Volumes, Stroke,Volumes, Ventricular End-Diastolic,Volumes, Ventricular End-Systolic
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography

Related Publications

S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
June 1987, Investigative radiology,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
October 1988, Cardiovascular and interventional radiology,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
January 1986, Journal of computer assisted tomography,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
October 1991, Journal of the American College of Cardiology,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
February 1994, Chest,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
April 1986, Angiology,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
April 1995, The American journal of cardiology,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
May 1978, Radiology,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
January 2011, Journal of cardiovascular computed tomography,
S J Reiter, and J A Rumberger, and A J Feiring, and W Stanford, and M L Marcus
March 1994, American heart journal,
Copied contents to your clipboard!