Interpolation time-optimized aortic pulse wave velocity estimation by 4D flow MRI. 2023

Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
Daegu-Gyeongbuk Medical Innovation Foundation, Medical Device Development Center, Daegu, 41061, South Korea.

Four-dimensional flow magnetic resonance imaging-based pulse wave velocity (4D flow PWV) estimation is a promising tool for measuring regional aortic stiffness for non-invasive cardiovascular disease screening. However, the effect of variations in the shape of flow waveforms on 4D flow PWV measurements remains unclear. In this study, 4D flow PWV values were compared using cross-correlation algorithm with different interpolation times (iTs) based on flow rate and beat frequency. A critical iT (iTCrit) was proposed from in vitro study using flexible and stiff phantom models to simultaneously achieve a low difference and a low computation time. In vivo 4D flow PWV values from six healthy volunteers were also compared between iTCrit and the conventionally used interpolation time of 1 ms (iT1 ms). The results indicated that iTCrit reduced the mean difference of in vitro 4D flow PWV values by 19%, compared to iT1 ms. In addition, iTCrit measured in vivo 4D flow PWV, showing differences similar to those obtained with iT1 ms. A difference estimation model was proposed to retrospectively estimate potential differences of 4D flow PWV using known values of PWV and the used iT. This study would be helpful for understanding the differences of PWV generated by physiological changes and time step of obtained flow waveforms.

UI MeSH Term Description Entries
D008279 Magnetic Resonance Imaging Non-invasive method of demonstrating internal anatomy based on the principle that atomic nuclei in a strong magnetic field absorb pulses of radiofrequency energy and emit them as radiowaves which can be reconstructed into computerized images. The concept includes proton spin tomographic techniques. Chemical Shift Imaging,MR Tomography,MRI Scans,MRI, Functional,Magnetic Resonance Image,Magnetic Resonance Imaging, Functional,Magnetization Transfer Contrast Imaging,NMR Imaging,NMR Tomography,Tomography, NMR,Tomography, Proton Spin,fMRI,Functional Magnetic Resonance Imaging,Imaging, Chemical Shift,Proton Spin Tomography,Spin Echo Imaging,Steady-State Free Precession MRI,Tomography, MR,Zeugmatography,Chemical Shift Imagings,Echo Imaging, Spin,Echo Imagings, Spin,Functional MRI,Functional MRIs,Image, Magnetic Resonance,Imaging, Magnetic Resonance,Imaging, NMR,Imaging, Spin Echo,Imagings, Chemical Shift,Imagings, Spin Echo,MRI Scan,MRIs, Functional,Magnetic Resonance Images,Resonance Image, Magnetic,Scan, MRI,Scans, MRI,Shift Imaging, Chemical,Shift Imagings, Chemical,Spin Echo Imagings,Steady State Free Precession MRI
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001011 Aorta The main trunk of the systemic arteries. Aortas
D012189 Retrospective Studies Studies used to test etiologic hypotheses in which inferences about an exposure to putative causal factors are derived from data relating to characteristics of persons under study or to events or experiences in their past. The essential feature is that some of the persons under study have the disease or outcome of interest and their characteristics are compared with those of unaffected persons. Retrospective Study,Studies, Retrospective,Study, Retrospective
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D059289 Vascular Stiffness Loss of vascular ELASTICITY due to factors such as AGING; and ARTERIOSCLEROSIS. Increased arterial stiffness is one of the RISK FACTORS for many CARDIOVASCULAR DISEASES. Arterial Stiffness,Aortic Stiffness,Aortic Stiffnesses,Arterial Stiffnesses,Stiffness, Aortic,Stiffness, Arterial,Stiffness, Vascular,Vascular Stiffnesses
D063177 Pulse Wave Analysis Evaluation of the contour of the PULSE waves which vary in different parts of the circulation and depend on physiological as well as pathophysiological conditions of the individual. Pulse Transit Time,Pulse Wave Transit Time,Pulse Wave Velocity,Analyses, Pulse Wave,Analysis, Pulse Wave,Pulse Transit Times,Pulse Wave Analyses,Pulse Wave Velocities,Time, Pulse Transit,Times, Pulse Transit,Transit Time, Pulse,Transit Times, Pulse,Velocities, Pulse Wave,Velocity, Pulse Wave,Wave Analyses, Pulse,Wave Analysis, Pulse,Wave Velocities, Pulse,Wave Velocity, Pulse

Related Publications

Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
June 2010, Magnetic resonance in medicine,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
August 2022, Journal of magnetic resonance imaging : JMRI,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
December 2018, Cardiovascular engineering and technology,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
August 2022, Journal of magnetic resonance imaging : JMRI,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
October 2021, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
April 2013, Journal of magnetic resonance imaging : JMRI,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
December 2019, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
December 2014, Magnetic resonance imaging,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
May 2021, Magnetic resonance in medicine,
Sungho Park, and Minseong Kwon, and Hyojin Nam, and Hyungkyu Huh
March 2011, Magnetic resonance in medicine,
Copied contents to your clipboard!