Evaluation of the Sysmex XQ-320 three-part differential haematology analyser and its flagging capabilities. 2024

Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
General Haematology Laboratory, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland.

BACKGROUND Three-part differential (3PD) haematology analysers offer a quick, easy-to-use and economical way to acquire important information about a patient's physiology. In this study, we evaluated a new 3PD analyser, the Sysmex XQ-320, investigated its comparability with its predecessor (Sysmex XP-300) and the five-part differential analyser Sysmex XN-9000, and explored its flagging potential. METHODS Analytical performance studies were conducted for repeatability, within-laboratory precision, between-day precision, carry-over and linearity with fresh blood and QC material. Method comparison was performed in 493 samples comparing XQ-320 with XP-300, using the XN-9000 as the gold standard. RESULTS The XQ-320 excelled manufacturer's specifications in the analytical performance studies, except for MXD in within-laboratory and between-day precisions using the QC material level 1. The XQ-320 showed correlation values greater than 0.94 with XN-9000 for the majority of the 20 reportable parameters (MXD# 0.891, MXD% 0.898 and MCHC 0.849). Improvements over the XP-300 were observed in WBC in the leucocytopenic range (bias -0.038 vs. -0.097) and PLT (bias 2.568 vs. -7.877, intercept 3.880 vs. -8.845). Concordance between XQ-320 and XP-300 was 91.9% for the WBC histogram abnormal distribution flag and 95.3% for the PLT flag. Patterns of increased neutrophils and decreased mixed cells on the XQ-320 were observed in samples that raised a flag on XN-9000. CONCLUSIONS The XQ-320 showed excellent analytical performance, and very good to excellent correlation with XN-9000 with improvements over XP-300. Flagging combined with parameter patterns identified additional suspected abnormal samples, thus making the XQ-320 an excellent solution for laboratories utilising 3PD analysers.

UI MeSH Term Description Entries

Related Publications

Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
April 2016, International journal of laboratory hematology,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
October 2020, Journal of clinical pathology,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
January 1989, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
May 1991, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
August 2001, Clinical and laboratory haematology,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
October 2009, International journal of laboratory hematology,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
March 2024, Practical laboratory medicine,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
January 2010, Acta clinica Belgica,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
October 1999, Clinical and laboratory haematology,
Christine Coutaz, and Adrien Mamin, and Konstantinos Mintzas
January 2013, British journal of biomedical science,
Copied contents to your clipboard!