Design Optimization of Printed Multi-Layered Electroactive Actuators Used for Steerable Guidewire in Micro-Invasive Surgery. 2024

Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
University Grenoble Alpes, CEA, LITEN DTNM, 38000 Grenoble, France.

To treat cardiovascular diseases (i.e., a major cause of mortality after cancers), endovascular-technique-based guidewire has been employed for intra-arterial navigation. To date, most commercially available guidewires (e.g., Terumo, Abbott, Cordis, etc.) are non-steerable, which is poorly suited to the human arterial system with numerous bifurcations and angulations. To reach a target artery, surgeons frequently opt for several tools (guidewires with different size integrated into angulated catheters) that might provoke arterial complications such as perforation or dissection. Steerable guidewires would, therefore, be of high interest to reduce surgical morbidity and mortality for patients as well as to simplify procedure for surgeons, thereby saving time and health costs. Regarding these reasons, our research involves the development of a smart steerable guidewire using electroactive polymer (EAP) capable of bending when subjected to an input voltage. The actuation performance of the developed device is assessed through the curvature behavior (i.e., the displacement and the angle of the bending) of a cantilever beam structure, consisting of single- or multi-stack EAP printed on a substrate. Compared to the single-stack architecture, the multi-stack gives rise to a significant increase in curvature, even when subjected to a moderate control voltage. As suggested by the design framework, the intrinsic physical properties (dielectric, electrical, and mechanical) of the EAP layer, together with the nature and thickness of all materials (EAP and substrate), do have strong effect on the bending response of the device. The analyses propose a comprehensive guideline to optimize the actuator performance based on an adequate selection of the relevant materials and geometric parameters. An analytical model together with a finite element model (FEM) are investigated to validate the experimental tests. Finally, the design guideline leads to an innovative structure (composed of a 10-stack active layer screen-printed on a thin substrate) capable of generating a large range of bending angle (up to 190°) under an acceptable input level of 550 V, which perfectly matches the standard of medical tools used for cardiovascular surgery.

UI MeSH Term Description Entries

Related Publications

Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
February 2010, ACS applied materials & interfaces,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
December 2021, Materials (Basel, Switzerland),
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
January 2019, Frontiers in robotics and AI,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
February 2021, IEEE transactions on bio-medical engineering,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
January 2022, PloS one,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
January 1999, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
January 2000, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
January 2015, Medical engineering & physics,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
October 2020, Soft robotics,
Simon Toinet, and Mohammed Benwadih, and Helga Szambolics, and Christine Revenant, and David Alincant, and Marine Bordet, and Jean-Fabien Capsal, and Nellie Della-Schiava, and Minh-Quyen Le, and Pierre-Jean Cottinet
August 2020, Journal of biomechanics,
Copied contents to your clipboard!