Proportional localization system for anatomical interpretation of cerebral computed tomograms. 1985

M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon

The existence of individual variations in size and shape of the human brain constitutes a problem for the anatomical interpretation of brain reconstructed images obtained from scanning devices; it is, for example, responsible for most of the inaccuracies in reading CT scans. One way to account for these variations is to use a proportional localization system. In the 1960s a group of neurosurgeons developed such a system based on two pivotal intracerebral structures, the anterior and the posterior commissures; they published an atlas consisting of horizontal, coronal, and sagittal brain sections interpreted in the proportional system. The atlas also included standard proportional brain schemes based on anatomical and radiological studies on large numbers of individuals. In this article we report a target localization experiment that we carried out to determine if this atlas could be used as a reference for a more accurate interpretation of CT and, eventually, of positron emission tomography (PET) and nuclear magnetic resonance (NMR) scans. Ten radiopaque small targets were inserted through the skull in the cortex of three cadavers; head CT was performed, and the atlas was used for predicting the cortical location of the targets seen on the CT images: The predictions were confirmed. These results strongly support the use of the proportional atlas for the interpretation of CT as well as of PET and NMR scans.

UI MeSH Term Description Entries
D008488 Medical Illustration The field which deals with illustrative clarification of biomedical concepts, as in the use of diagrams and drawings. The illustration may be produced by hand, photography, computer, or other electronic or mechanical methods. Illustration, Medical,Illustrations, Medical,Medical Illustrations
D009682 Magnetic Resonance Spectroscopy Spectroscopic method of measuring the magnetic moment of elementary particles such as atomic nuclei, protons or electrons. It is employed in clinical applications such as NMR Tomography (MAGNETIC RESONANCE IMAGING). In Vivo NMR Spectroscopy,MR Spectroscopy,Magnetic Resonance,NMR Spectroscopy,NMR Spectroscopy, In Vivo,Nuclear Magnetic Resonance,Spectroscopy, Magnetic Resonance,Spectroscopy, NMR,Spectroscopy, Nuclear Magnetic Resonance,Magnetic Resonance Spectroscopies,Magnetic Resonance, Nuclear,NMR Spectroscopies,Resonance Spectroscopy, Magnetic,Resonance, Magnetic,Resonance, Nuclear Magnetic,Spectroscopies, NMR,Spectroscopy, MR
D001921 Brain The part of CENTRAL NERVOUS SYSTEM that is contained within the skull (CRANIUM). Arising from the NEURAL TUBE, the embryonic brain is comprised of three major parts including PROSENCEPHALON (the forebrain); MESENCEPHALON (the midbrain); and RHOMBENCEPHALON (the hindbrain). The developed brain consists of CEREBRUM; CEREBELLUM; and other structures in the BRAIN STEM. Encephalon
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000716 Anatomy, Artistic The study of the structures of organisms for applications in art: drawing, painting, sculpture, illustration, etc. Artistic Anatomy,Anatomies, Artistic,Artistic Anatomies
D014055 Tomography, Emission-Computed Tomography using radioactive emissions from injected RADIONUCLIDES and computer ALGORITHMS to reconstruct an image. CAT Scan, Radionuclide,CT Scan, Radionuclide,Computerized Emission Tomography,Radionuclide Tomography, Computed,Scintigraphy, Computed Tomographic,Tomography, Radionuclide-Computed,Computed Tomographic Scintigraphy,Emission-Computed Tomography,Radionuclide Computer-Assisted Tomography,Radionuclide Computerized Tomography,Radionuclide-Computed Tomography,Radionuclide-Emission Computed Tomography,Tomography, Computerized Emission,CAT Scans, Radionuclide,CT Scans, Radionuclide,Computed Radionuclide Tomography,Computed Tomography, Radionuclide-Emission,Computer-Assisted Tomographies, Radionuclide,Computer-Assisted Tomography, Radionuclide,Computerized Tomography, Radionuclide,Emission Computed Tomography,Emission Tomography, Computerized,Radionuclide CAT Scan,Radionuclide CAT Scans,Radionuclide CT Scan,Radionuclide CT Scans,Radionuclide Computed Tomography,Radionuclide Computer Assisted Tomography,Radionuclide Computer-Assisted Tomographies,Radionuclide Emission Computed Tomography,Scan, Radionuclide CAT,Scan, Radionuclide CT,Scans, Radionuclide CAT,Scans, Radionuclide CT,Tomographic Scintigraphy, Computed,Tomographies, Radionuclide Computer-Assisted,Tomography, Computed Radionuclide,Tomography, Emission Computed,Tomography, Radionuclide Computed,Tomography, Radionuclide Computer-Assisted,Tomography, Radionuclide Computerized,Tomography, Radionuclide-Emission Computed
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography

Related Publications

M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
September 1978, Journal of computer assisted tomography,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
July 1978, Journal of computer assisted tomography,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
August 1996, European journal of nuclear medicine,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
January 1981, Vestnik rentgenologii i radiologii,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
January 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
December 1993, Journal of periodontology,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
January 1989, Journal of computer assisted tomography,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
October 1977, Journal of computer assisted tomography,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
April 1982, Radiology,
M Vanier, and A R Lecours, and R Ethier, and M Habib, and M Poncet, and P C Milette, and G Salamon
February 1953, Gruzlica (Warsaw, Poland : 1926),
Copied contents to your clipboard!