Evaluation of fluorescence polarization immunoassay for quantitation of serum salicylates. 1985

H T Karnes, and L A Beightol

A fluorescence polarization immunoassay (FPIA) for serum salicylates that has been developed for use with the Abbott TDx analyzer is evaluated with regard to precision, accuracy, and stability of the standard curve. The FPIA method is also compared with a well-established high performance liquid chromatography (HPLC) technique in a clinical laboratory environment. The FPIA demonstrates excellent precision, and the standard curve is sufficiently stable to perform reproducible measurements over a 29-day period without recalibration. Superior accuracy of the FPIA method is indicated for salicylate concentrations between 50 and 800 micrograms/ml by recovery studies and by favorable comparison with the reference method. The performance of the FPIA for salicylate concentrations between 0 and 50 micrograms/ml is somewhat less favorable and should be used with caution in this range. The present method is more appropriate than HPLC for the management of patients receiving chronic high doses of salicylates or in cases of acute salicylate overdose and is also more rapid.

UI MeSH Term Description Entries
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005454 Fluorescence Polarization Measurement of the polarization of fluorescent light from solutions or microscopic specimens. It is used to provide information concerning molecular size, shape, and conformation, molecular anisotropy, electronic energy transfer, molecular interaction, including dye and coenzyme binding, and the antigen-antibody reaction. Anisotropy, Fluorescence,Fluorescence Anisotropy,Polarization, Fluorescence,Anisotropies, Fluorescence,Fluorescence Anisotropies,Fluorescence Polarizations,Polarizations, Fluorescence
D005455 Fluorescent Antibody Technique Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy. Antinuclear Antibody Test, Fluorescent,Coon's Technique,Fluorescent Antinuclear Antibody Test,Fluorescent Protein Tracing,Immunofluorescence Technique,Coon's Technic,Fluorescent Antibody Technic,Immunofluorescence,Immunofluorescence Technic,Antibody Technic, Fluorescent,Antibody Technics, Fluorescent,Antibody Technique, Fluorescent,Antibody Techniques, Fluorescent,Coon Technic,Coon Technique,Coons Technic,Coons Technique,Fluorescent Antibody Technics,Fluorescent Antibody Techniques,Fluorescent Protein Tracings,Immunofluorescence Technics,Immunofluorescence Techniques,Protein Tracing, Fluorescent,Protein Tracings, Fluorescent,Technic, Coon's,Technic, Fluorescent Antibody,Technic, Immunofluorescence,Technics, Fluorescent Antibody,Technics, Immunofluorescence,Technique, Coon's,Technique, Fluorescent Antibody,Technique, Immunofluorescence,Techniques, Fluorescent Antibody,Techniques, Immunofluorescence,Tracing, Fluorescent Protein,Tracings, Fluorescent Protein
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012459 Salicylates The salts or esters of salicylic acids, or salicylate esters of an organic acid. Some of these have analgesic, antipyretic, and anti-inflammatory activities by inhibiting prostaglandin synthesis. Salicylate,Salicylic Acids,Acids, Salicylic

Related Publications

H T Karnes, and L A Beightol
January 1984, Therapeutic drug monitoring,
H T Karnes, and L A Beightol
January 1986, Therapeutic drug monitoring,
H T Karnes, and L A Beightol
August 1982, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie,
H T Karnes, and L A Beightol
August 1991, Antimicrobial agents and chemotherapy,
H T Karnes, and L A Beightol
August 1983, Antimicrobial agents and chemotherapy,
H T Karnes, and L A Beightol
September 1993, Antimicrobial agents and chemotherapy,
H T Karnes, and L A Beightol
January 1984, Journal of analytical toxicology,
H T Karnes, and L A Beightol
January 1993, Diagnostic microbiology and infectious disease,
H T Karnes, and L A Beightol
January 1990, Journal - Association of Official Analytical Chemists,
Copied contents to your clipboard!