Some factors affecting bubble formation with catheter-mediated defibrillator pulses. 1986

G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene

Factors affecting bubble formation during delivery of defibrillator pulses to arrhythmogenic cardiac tissue via a catheter are unknown. We investigated the role of energy, electrode surface area, interelectrode distance, and electrode polarity on bubble formation and on current and voltage waveforms during delivery of damped sinusoidal discharges from a standard defibrillator to anticoagulated bovine blood. Gas composition was studied with mass spectrometry. Defibrillator energy settings were varied between 5 and 360 J. The principal catheter used for study was a Medtronic 6992A lead. Additional electrodes tested included 2, 5, and 10 mm long No. 6F, 7F, and 8F copper electrodes. Interelectrode distances used to assess the effect of anode-cathode spacing were 1, 5, 10, and 20 cm. Bubble volume increased linearly from 0.043 to 0.134 ml per cathodal pulse and from 0.030 to 3.50 ml per anodal pulse as energy settings were increased from 5 to 360 J (r = .99). Typical smooth waveforms for both current and voltage were seen only in the absence of bubbles. The voltage waveform was distorted for each cathodal pulse of 100 J or more and for each anodal pulse of 10 J or more only if bubbles were present. The effect of electrode surface area on bubble formation was tested at a 200 J energy setting and at a 10 cm interelectrode distance with the use of cathodal pulses. Bubble formation varied inversely with electrode surface area (r = .876). Bubble formation, however, varied minimally as interelectrode spacing was changed from 1 to 20 cm. The effect of polarity on bubble formation when the Medtronic 6992A distal electrode and an 8.5 cm disk electrode separated by 10 cm were used was highly significant. For a 200 J pulse, bubble formation with the catheter as anode was 3.30 +/- 0.10 ml and with the catheter as cathode it was 0.070 +/- 0.002 ml (p less than .001). Mass spectrometry of both anodal and cathodal gas samples demonstrated the constituents of the gas bubble to include a variety of gases, which is inconsistent with simple electrolytic production of the bubbles observed. The predominance of nitrogen in either polarity sample suggested that the principal source of the bubble was dissolved air. In summary, bubble formation at an electrode receiving damped sinusoidal outputs from a standard defibrillator does not vary significantly with varying interelectrode distance. However, it is directly proportional to energy and inversely proportional to electrode surface area. Anodal catheter discharges produce considerably more bubbles than do cathodal discharges.(ABSTRACT TRUNCATED AT 400 WORDS)

UI MeSH Term Description Entries
D008954 Models, Biological Theoretical representations that simulate the behavior or activity of biological processes or diseases. For disease models in living animals, DISEASE MODELS, ANIMAL is available. Biological models include the use of mathematical equations, computers, and other electronic equipment. Biological Model,Biological Models,Model, Biological,Models, Biologic,Biologic Model,Biologic Models,Model, Biologic
D002404 Catheterization Use or insertion of a tubular device into a duct, blood vessel, hollow organ, or body cavity for injecting or withdrawing fluids for diagnostic or therapeutic purposes. It differs from INTUBATION in that the tube here is used to restore or maintain patency in obstructions. Cannulation,Cannulations,Catheterizations
D004554 Electric Countershock An electrical current applied to the HEART to terminate a CARDIAC ARRHYTHMIA. Cardiac Electroversion,Cardioversion,Defibrillation, Electric,Electroversion, Cardiac,Electrical Cardioversion,Electroversion Therapy,Therapy, Electroversion,Cardiac Electroversions,Cardioversion, Electrical,Cardioversions,Cardioversions, Electrical,Countershock, Electric,Countershocks, Electric,Defibrillations, Electric,Electric Countershocks,Electric Defibrillation,Electric Defibrillations,Electrical Cardioversions,Electroversion Therapies,Electroversions, Cardiac,Therapies, Electroversion
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D004618 Embolism, Air Blocking of a blood vessel by air bubbles that enter the circulatory system, usually after TRAUMA; surgical procedures, or changes in atmospheric pressure. Air Embolism,Embolism, Gas,Air Embolisms,Embolisms, Air,Embolisms, Gas,Gas Embolism,Gas Embolisms

Related Publications

G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
June 1960, The Journal of pharmacology and experimental therapeutics,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
October 1975, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
November 1958, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine (New York, N.Y.),
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
May 1962, Journal of bacteriology,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
August 1957, Journal of experimental psychology,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
September 1965, The Biochemical journal,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
June 2017, Physical chemistry chemical physics : PCCP,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
April 1956, Journal of general microbiology,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
March 2006, Food additives and contaminants,
G H Bardy, and F Coltorti, and T D Ivey, and C Alferness, and M Rackson, and K Hansen, and R Stewart, and H L Greene
January 1968, Folia microbiologica,
Copied contents to your clipboard!