Evaluation of a new dynamic viscometer for measuring the viscosity of whole blood and plasma. 1986

W L Chandler, and G Schmer

We evaluated a new type of dynamic viscometer, the Sonoclot Coagulation Analyzer, for use in measuring the viscosity of whole-blood and plasma. Such information can be useful in monitoring patients with hyperviscosity syndromes, e.g., from multiple myeloma. A vibrating Teflon or plastic probe continuously measures dynamic viscosity. The instrument can be calibrated to measure a range of viscosities from 0.69 to 23 cP (mN X s X m-2) or more. The coefficient of variation at 0.69 cP was 3-4% for measurements with the Teflon probe, 7-9% with the plastic probe. Viscosity measured at 37 degrees C for plasma and whole-blood samples from 20 normal patients was 1.22 (SD 0.05) cP and 3.63 (SD 0.52) cP, respectively. Dynamic viscosity measured in blood samples from a single source, with contrived hematocrits ranging from 0 to 89%, increased exponentially as a function of hematocrit, confirming previous studies. Overall, we found this instrument simple and quick to operate, producing accurate, precise viscosity measurements over at least a 40-fold range of viscosity.

UI MeSH Term Description Entries
D010949 Plasma The residual portion of BLOOD that is left after removal of BLOOD CELLS by CENTRIFUGATION without prior BLOOD COAGULATION. Blood Plasma,Fresh Frozen Plasma,Blood Plasmas,Fresh Frozen Plasmas,Frozen Plasma, Fresh,Frozen Plasmas, Fresh,Plasma, Blood,Plasma, Fresh Frozen,Plasmas,Plasmas, Blood,Plasmas, Fresh Frozen
D001809 Blood Viscosity The internal resistance of the BLOOD to shear forces. The in vitro measure of whole blood viscosity is of limited clinical utility because it bears little relationship to the actual viscosity within the circulation, but an increase in the viscosity of circulating blood can contribute to morbidity in patients suffering from disorders such as SICKLE CELL ANEMIA and POLYCYTHEMIA. Blood Viscosities,Viscosities, Blood,Viscosity, Blood
D004864 Equipment and Supplies Expendable and nonexpendable equipment, supplies, apparatus, and instruments that are used in diagnostic, surgical, therapeutic, scientific, and experimental procedures. Apparatus and Instruments,Devices,Medical Devices,Device, Medical,Devices, Medical,Equipment,Inventories,Medical Device,Supplies,Device,Instruments and Apparatus,Inventory,Supplies and Equipment
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006400 Hematocrit The volume of packed RED BLOOD CELLS in a blood specimen. The volume is measured by centrifugation in a tube with graduated markings, or with automated blood cell counters. It is an indicator of erythrocyte status in disease. For example, ANEMIA shows a low value; POLYCYTHEMIA, a high value. Erythrocyte Volume, Packed,Packed Red-Cell Volume,Erythrocyte Volumes, Packed,Hematocrits,Packed Erythrocyte Volume,Packed Erythrocyte Volumes,Packed Red Cell Volume,Packed Red-Cell Volumes,Red-Cell Volume, Packed,Red-Cell Volumes, Packed,Volume, Packed Erythrocyte,Volume, Packed Red-Cell,Volumes, Packed Erythrocyte,Volumes, Packed Red-Cell
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

W L Chandler, and G Schmer
January 1984, Biorheology. Supplement : the official journal of the International Society of Biorheology,
W L Chandler, and G Schmer
June 2003, Clinica chimica acta; international journal of clinical chemistry,
W L Chandler, and G Schmer
January 1973, Bulletin de physio-pathologie respiratoire,
W L Chandler, and G Schmer
January 1999, Biorheology,
W L Chandler, and G Schmer
June 2017, Sensors (Basel, Switzerland),
W L Chandler, and G Schmer
January 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine,
W L Chandler, and G Schmer
January 1965, Suomen Hammaslaakariseuran toimituksia = Finska tandlakarsallskapets forhandlingar,
W L Chandler, and G Schmer
November 1976, British journal of haematology,
W L Chandler, and G Schmer
January 1996, Biorheology,
Copied contents to your clipboard!