Failure of silicone rubber wrist arthroplasty in rheumatoid arthritis. 1986

D W Brase, and L H Millender

Of 71 silicone rubber wrist arthroplasties performed between 1976 and 1983, 20% were found to have fractured, and an additional 5% required revision for deformity and pain. In most cases, no specific cause for the failure could be identified. However, excessive wrist motion, overuse, and inadequate surgical technique appear to be contributory. Prosthetic fracture is associated with increasing wrist pain, instability, and deformity with decreasing strength and function. Twelve of 14 fractured prostheses required revision. Eleven of these were revised with another silicone rubber implant, and two of these have refractured. Based on this review, we have narrowed our indications for silicone rubber wrist arthroplasty and now give greater consideration to alternative methods of treatment.

UI MeSH Term Description Entries
D007595 Joint Prosthesis Prostheses used to partially or totally replace a human or animal joint. (from UMDNS, 1999) Joint Prostheses,Prostheses, Joint,Prosthesis, Joint
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001172 Arthritis, Rheumatoid A chronic systemic disease, primarily of the joints, marked by inflammatory changes in the synovial membranes and articular structures, widespread fibrinoid degeneration of the collagen fibers in mesenchymal tissues, and by atrophy and rarefaction of bony structures. Etiology is unknown, but autoimmune mechanisms have been implicated. Rheumatoid Arthritis
D001174 Arthrodesis The surgical fixation of a joint by a procedure designed to accomplish fusion of the joint surfaces by promoting the proliferation of bone cells. (Dorland, 28th ed) Arthrodeses
D012826 Silicone Elastomers Polymers of silicone that are formed by crosslinking and treatment with amorphous silica to increase strength. They have properties similar to vulcanized natural rubber, in that they stretch under tension, retract rapidly, and fully recover to their original dimensions upon release. They are used in the encapsulation of surgical membranes and implants. Elastomers, Silicone,Rubber Silicone,Silicone Rubber,Elastosil,Microfil,SE-30,Elastosils,Microfils,SE 30,SE30,Silicone Elastomer
D014955 Wrist Joint The joint that is formed by the distal end of the RADIUS, the articular disc of the distal radioulnar joint, and the proximal row of CARPAL BONES; (SCAPHOID BONE; LUNATE BONE; triquetral bone). Joint, Wrist,Joints, Wrist,Wrist Joints

Related Publications

D W Brase, and L H Millender
January 1993, The Journal of hand surgery,
D W Brase, and L H Millender
April 1991, Seminars in arthroplasty,
D W Brase, and L H Millender
March 1980, The Journal of hand surgery,
D W Brase, and L H Millender
January 1987, The Journal of hand surgery,
D W Brase, and L H Millender
April 1972, Tijdschrift voor ziekenverpleging,
D W Brase, and L H Millender
November 1971, Nederlands tijdschrift voor geneeskunde,
D W Brase, and L H Millender
February 1986, The Journal of bone and joint surgery. American volume,
D W Brase, and L H Millender
November 2005, The Journal of hand surgery,
D W Brase, and L H Millender
January 1973, Clinical orthopaedics and related research,
Copied contents to your clipboard!