The determination of electron density by the dual-energy Compton scatter method. 1985

A L Huddleston, and J P Sackler

The intensity of Compton scattered photons is directly proportional to the electron density of a substance; therefore it is possible to detect changes in electron density by this noninvasive method. The source-detector geometry has been varied to study the effects of geometry on the calculated electron density values, using a 90 degrees scattering angle. The dual-energy Compton scatter method provides a determination of electron density in known samples, with an uncertainty of less than 1% for the optimal geometry. The effective linear attenuation coefficient for Compton scatter has been determined with an uncertainty of 2.1%-3.6% for the optimal geometry used. The applications of the dual-energy Compton scattering technique in radiotherapy dosimetry and skeletal bone densitometry are being investigated.

UI MeSH Term Description Entries
D008433 Mathematics The deductive study of shape, quantity, and dependence. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Mathematic
D011827 Radiation Emission or propagation of acoustic waves (SOUND), ELECTROMAGNETIC ENERGY waves (such as LIGHT; RADIO WAVES; GAMMA RAYS; or X-RAYS), or a stream of subatomic particles (such as ELECTRONS; NEUTRONS; PROTONS; or ALPHA PARTICLES). Radiations
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D004583 Electrons Stable elementary particles having the smallest known negative charge, present in all elements; also called negatrons. Positively charged electrons are called positrons. The numbers, energies and arrangement of electrons around atomic nuclei determine the chemical identities of elements. Beams of electrons are called CATHODE RAYS. Fast Electrons,Negatrons,Positrons,Electron,Electron, Fast,Electrons, Fast,Fast Electron,Negatron,Positron
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012542 Scattering, Radiation The diversion of RADIATION (thermal, electromagnetic, or nuclear) from its original path as a result of interactions or collisions with atoms, molecules, or larger particles in the atmosphere or other media. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Radiation Scattering,Radiation Scatterings,Scatterings, Radiation
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography

Related Publications

A L Huddleston, and J P Sackler
May 1986, Physics in medicine and biology,
A L Huddleston, and J P Sackler
December 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A L Huddleston, and J P Sackler
January 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A L Huddleston, and J P Sackler
April 2020, Sensors (Basel, Switzerland),
A L Huddleston, and J P Sackler
January 1976, Medical physics,
A L Huddleston, and J P Sackler
September 1981, Physics in medicine and biology,
A L Huddleston, and J P Sackler
January 1980, Medical physics,
A L Huddleston, and J P Sackler
March 1989, Australasian physical & engineering sciences in medicine,
A L Huddleston, and J P Sackler
June 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
Copied contents to your clipboard!