Flow cytometric enumeration of absolute lymphocyte number in peripheral blood using two parameters of light scatter. 1985

Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton

A method was developed to measure the absolute lymphocyte count (ALC) of whole blood using the Spectrum III automated flow cytometer. Ninety-nine samples of human peripheral blood were analysed on the Spectrum and the Coulter Counter S Plus II, to allow for comparison of the two machines. Regression analysis was used to test the extent of agreement between the sets of measurements on the two machines. The results demonstrated that the slope of the regression line was not significantly different from one, indicating a high level of correlation between Spectrum and Coulter ALC's. However, the mean difference between Coulter and Spectrum ALC's was not equal to zero, with the Spectrum giving counts approximately 10% lower than those of the Coulter machine. This is attributed to the different ways by which the two machines define a lymphocyte, the Spectrum III by two parameters of light scatter and the Coulter S Plus II by the single parameter of cell volume.

UI MeSH Term Description Entries
D007958 Leukocyte Count The number of WHITE BLOOD CELLS per unit volume in venous BLOOD. A differential leukocyte count measures the relative numbers of the different types of white cells. Blood Cell Count, White,Differential Leukocyte Count,Leukocyte Count, Differential,Leukocyte Number,White Blood Cell Count,Count, Differential Leukocyte,Count, Leukocyte,Counts, Differential Leukocyte,Counts, Leukocyte,Differential Leukocyte Counts,Leukocyte Counts,Leukocyte Counts, Differential,Leukocyte Numbers,Number, Leukocyte,Numbers, Leukocyte
D008027 Light That portion of the electromagnetic spectrum in the visible, ultraviolet, and infrared range. Light, Visible,Photoradiation,Radiation, Visible,Visible Radiation,Photoradiations,Radiations, Visible,Visible Light,Visible Radiations
D008214 Lymphocytes White blood cells formed in the body's lymphoid tissue. The nucleus is round or ovoid with coarse, irregularly clumped chromatin while the cytoplasm is typically pale blue with azurophilic (if any) granules. Most lymphocytes can be classified as either T or B (with subpopulations of each), or NATURAL KILLER CELLS. Lymphoid Cells,Cell, Lymphoid,Cells, Lymphoid,Lymphocyte,Lymphoid Cell
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012542 Scattering, Radiation The diversion of RADIATION (thermal, electromagnetic, or nuclear) from its original path as a result of interactions or collisions with atoms, molecules, or larger particles in the atmosphere or other media. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Radiation Scattering,Radiation Scatterings,Scatterings, Radiation

Related Publications

Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
January 1992, Cytometry,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
February 2000, Mutation research,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
March 1992, American journal of clinical pathology,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
March 1986, Cytometry,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
January 1992, International archives of allergy and immunology,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
September 2001, Veterinary immunology and immunopathology,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
May 2000, Clinical and diagnostic laboratory immunology,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
April 1994, Bone marrow transplantation,
Y C Smart, and J Cox, and B Murphy, and A Enno, and R C Burton
December 1985, Rinsho byori. The Japanese journal of clinical pathology,
Copied contents to your clipboard!