High-performance liquid chromatographic strategies for the determination and confirmation of anticoagulant rodenticide residues in animal tissues. 1985

K Hunter

A comprehensive approach to the analysis of anticoagulant rodenticide residues in animal tissues based on high-performance liquid chromatography (HPLC) has been developed. Residues of warfarin, coumatetralyl, difenacoum, brodifacoum, bromadiolone, diphacinone and chlorophacinone were extracted with chloroformacetone (1:1, v/v). Extracts were cleaned-up by an integrated gel permeation and adsorption chromatographic procedure which divided the rodenticides into two groups. Residues were then determined and confirmed using normal-phase, ion-pair and weak ion-exchange HPLC techniques. Ion-pair gradient separation resolved all seven rodenticides in a single chromatographic analysis. UV detection methods were employed for all seven rodenticides. Use of a diode array detection system permitted additional confirmation of residues down to 0.1 mg kg-1 by matching UV spectra and derivatives of spectra. Sensitive fluorescence detection was possible for the coumarin-based rodenticides but not for diphacinone and chlorophacinone. Post-column pH-switching fluorescence detection methods were shown to be superior to other methods of fluorescence detection of coumarin-based rodenticides. Recoveries from spiked liver tissue were around 90% at levels from 0.05 to 1 mg kg-1. Detection limits of around 0.002 mg kg-1 for most rodenticides and of 0.01 mg kg-1 for warfarin could be achieved with animal tissue extracts.

UI MeSH Term Description Entries
D007189 Indans Aryl CYCLOPENTANES that are a reduced (protonated) form of INDENES. Indanones
D008099 Liver A large lobed glandular organ in the abdomen of vertebrates that is responsible for detoxification, metabolism, synthesis and storage of various substances. Livers
D010573 Pesticide Residues Pesticides or their breakdown products remaining in the environment following their normal use or accidental contamination. Pesticide Residue,Residue, Pesticide,Residues, Pesticide
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D002852 Chromatography, Ion Exchange Separation technique in which the stationary phase consists of ion exchange resins. The resins contain loosely held small ions that easily exchange places with other small ions of like charge present in solutions washed over the resins. Chromatography, Ion-Exchange,Ion-Exchange Chromatography,Chromatographies, Ion Exchange,Chromatographies, Ion-Exchange,Ion Exchange Chromatographies,Ion Exchange Chromatography,Ion-Exchange Chromatographies
D003374 Coumarins Synthetic or naturally occurring substances related to coumarin, the delta-lactone of coumarinic acid. 1,2-Benzopyrone Derivatives,1,2-Benzopyrones,Coumarin Derivative,Coumarine,1,2-Benzo-Pyrones,Benzopyran-2-ones,Coumarin Derivatives,Coumarines,1,2 Benzo Pyrones,1,2 Benzopyrone Derivatives,1,2 Benzopyrones,Benzopyran 2 ones,Derivative, Coumarin,Derivatives, 1,2-Benzopyrone,Derivatives, Coumarin
D004285 Dogs The domestic dog, Canis familiaris, comprising about 400 breeds, of the carnivore family CANIDAE. They are worldwide in distribution and live in association with people. (Walker's Mammals of the World, 5th ed, p1065) Canis familiaris,Dog
D005777 Geese Any of various large waterfowl in the order Anseriformes, especially those of the genera Anser (gray geese) and Branta (black geese). They are larger than ducks but smaller than swans, prefer FRESH WATER, and occur primarily in the northern hemisphere. Goose,Gooses
D006863 Hydrogen-Ion Concentration The normality of a solution with respect to HYDROGEN ions; H+. It is related to acidity measurements in most cases by pH pH,Concentration, Hydrogen-Ion,Concentrations, Hydrogen-Ion,Hydrogen Ion Concentration,Hydrogen-Ion Concentrations
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia

Related Publications

K Hunter
January 1996, Bulletin of environmental contamination and toxicology,
K Hunter
September 1980, Journal - Association of Official Analytical Chemists,
K Hunter
January 1981, Journal - Association of Official Analytical Chemists,
K Hunter
January 1982, Journal - Association of Official Analytical Chemists,
K Hunter
January 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Copied contents to your clipboard!