Intraoperative evoked potentials recorded in man directly from dorsal roots and spinal cord. 1985

B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins

Direct spinal cord surface recordings of evoked spinal cord potentials have been made in 26 patients during neurosurgical procedures for intractable pain. Monopolar recordings at the dorsal root entry zone after peripheral nerve stimulation have been made at multiple levels for segmental localization and to monitor the state of the afferent path and dorsal horn. Dorsal root and dorsal column conduction has been tested on diseased and intact sides. Normal afferent conduction velocity was found to have an overall mean of 61.33 m/sec for cervicothoracic and lumbosacral peripheral nerves, and 50 m/sec for the dorsal columns. The normal mean amplitude for the slow negative wave (N1) recorded at the root entry was 52.54 muV, while that for the dorsal column conducted response recorded within 4 cm of the stimulus point on the dorsal columns was 347.5 muV. Several different placements of stimulating and recording electrodes are described, as well as their application. An interpretation of the resulting data is proposed.

UI MeSH Term Description Entries
D007432 Intraoperative Period The period during a surgical operation. Intraoperative Periods,Period, Intraoperative,Periods, Intraoperative
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009431 Neural Conduction The propagation of the NERVE IMPULSE along the nerve away from the site of an excitation stimulus. Nerve Conduction,Conduction, Nerve,Conduction, Neural,Conductions, Nerve,Conductions, Neural,Nerve Conductions,Neural Conductions
D010148 Pain, Intractable Persistent pain that is refractory to some or all forms of treatment. Refractory Pain,Intractable Pain,Intractable Pains,Pain, Refractory,Pains, Intractable,Pains, Refractory,Refractory Pains
D010525 Peripheral Nerves The nerves outside of the brain and spinal cord, including the autonomic, cranial, and spinal nerves. Peripheral nerves contain non-neuronal cells and connective tissue as well as axons. The connective tissue layers include, from the outside to the inside, the epineurium, the perineurium, and the endoneurium. Endoneurium,Epineurium,Perineurium,Endoneuriums,Epineuriums,Nerve, Peripheral,Nerves, Peripheral,Perineuriums,Peripheral Nerve
D004558 Electric Stimulation Use of electric potential or currents to elicit biological responses. Stimulation, Electric,Electrical Stimulation,Electric Stimulations,Electrical Stimulations,Stimulation, Electrical,Stimulations, Electric,Stimulations, Electrical
D005071 Evoked Potentials Electrical responses recorded from nerve, muscle, SENSORY RECEPTOR, or area of the CENTRAL NERVOUS SYSTEM following stimulation. They range from less than a microvolt to several microvolts. The evoked potential can be auditory (EVOKED POTENTIALS, AUDITORY), somatosensory (EVOKED POTENTIALS, SOMATOSENSORY), visual (EVOKED POTENTIALS, VISUAL), or motor (EVOKED POTENTIALS, MOTOR), or other modalities that have been reported. Event Related Potential,Event-Related Potentials,Evoked Potential,N100 Evoked Potential,P50 Evoked Potential,N1 Wave,N100 Evoked Potentials,N2 Wave,N200 Evoked Potentials,N3 Wave,N300 Evoked Potentials,N4 Wave,N400 Evoked Potentials,P2 Wave,P200 Evoked Potentials,P50 Evoked Potentials,P50 Wave,P600 Evoked Potentials,Potentials, Event-Related,Event Related Potentials,Event-Related Potential,Evoked Potential, N100,Evoked Potential, N200,Evoked Potential, N300,Evoked Potential, N400,Evoked Potential, P200,Evoked Potential, P50,Evoked Potential, P600,Evoked Potentials, N100,Evoked Potentials, N200,Evoked Potentials, N300,Evoked Potentials, N400,Evoked Potentials, P200,Evoked Potentials, P50,Evoked Potentials, P600,N1 Waves,N2 Waves,N200 Evoked Potential,N3 Waves,N300 Evoked Potential,N4 Waves,N400 Evoked Potential,P2 Waves,P200 Evoked Potential,P50 Waves,P600 Evoked Potential,Potential, Event Related,Potential, Event-Related,Potential, Evoked,Potentials, Event Related,Potentials, Evoked,Potentials, N400 Evoked,Related Potential, Event,Related Potentials, Event,Wave, N1,Wave, N2,Wave, N3,Wave, N4,Wave, P2,Wave, P50,Waves, N1,Waves, N2,Waves, N3,Waves, N4,Waves, P2,Waves, P50
D005260 Female Females

Related Publications

B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
November 1988, Pain,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
January 1987, Neurosurgery,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
January 1991, Electroencephalography and clinical neurophysiology,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
July 1981, IEEE transactions on bio-medical engineering,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
January 1979, Spine,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
January 2013, Neuromodulation : journal of the International Neuromodulation Society,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
November 1995, Spine,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
January 1997, Neurologia i neurochirurgia polska,
B S Nashold, and J Ovelmen-Levitt, and R Sharpe, and A C Higgins
October 2004, Journal of spinal disorders & techniques,
Copied contents to your clipboard!