Sequential hemodynamic studies in patients having aortic valve replacement with the Ionescu-Shiley pericardial xenograft. 1977

A P Tandon, and D R Smith, and D A Mary, and M I Ionescu

Sequential hemodynamic studies were performed in 13 patients having aortic valve replacement with glutaraldehyde-stabilized pericardial xenografts. The investigation done preoperatively was repeated twice in all patients at mean intervals of 9.9 and 42.2 months following valve replacement. Annulus diameters of the valves were 19, 23, and 25 mm. Between the preoperative and the first postoperative investigation there was a significant increase in cardiac index (p less than 0.05) and a significant reduction in both pulmonary wedge and left ventricular end-diastolic pressures (p less than 0.01). At the first postoperative study the mean ejection systolic gradient across the three sizes of aortic pericardial xenograft was 7, 15.7, and 8.4 mm Hg at rest and 10, 19.6, and 13.7 mm Hg on exercise, respectively. The corresponding surface areas of the three valve sizes were 1.1, 1.5, and 1.62 cm2 at rest and 1.4, 2.1, and 2.03 cm2 on exercise. There was no significant change in any of these measurements between the first and the second postoperative study. The results have shown considerable postoperative hemodynamic improvement, insignificant transvalvular pressure gradients, and maintenance of the functional integrity of the pericardial xenograft up to 56 months following valve insertion.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D010496 Pericardium A conical fibro-serous sac surrounding the HEART and the roots of the great vessels (AORTA; VENAE CAVAE; PULMONARY ARTERY). Pericardium consists of two sacs: the outer fibrous pericardium and the inner serous pericardium. The latter consists of an outer parietal layer facing the fibrous pericardium, and an inner visceral layer (epicardium) resting next to the heart, and a pericardial cavity between these two layers. Epicardium,Fibrous Pericardium,Parietal Pericardium,Pericardial Cavity,Pericardial Space,Serous Pericardium,Visceral Pericardium,Cavities, Pericardial,Cavity, Pericardial,Pericardial Cavities,Pericardial Spaces,Pericardium, Fibrous,Pericardium, Parietal,Pericardium, Serous,Pericardium, Visceral,Pericardiums, Fibrous,Pericardiums, Serous,Serous Pericardiums,Space, Pericardial,Spaces, Pericardial
D011859 Radiography Examination of any part of the body for diagnostic purposes by means of X-RAYS or GAMMA RAYS, recording the image on a sensitized surface (such as photographic film). Radiology, Diagnostic X-Ray,Roentgenography,X-Ray, Diagnostic,Diagnostic X-Ray,Diagnostic X-Ray Radiology,X-Ray Radiology, Diagnostic,Diagnostic X Ray,Diagnostic X Ray Radiology,Diagnostic X-Rays,Radiology, Diagnostic X Ray,X Ray Radiology, Diagnostic,X Ray, Diagnostic,X-Rays, Diagnostic
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females
D005976 Glutaral One of the protein CROSS-LINKING REAGENTS that is used as a disinfectant for sterilization of heat-sensitive equipment and as a laboratory reagent, especially as a fixative. Glutaraldehyde,Cidex,Diswart,Gludesin,Glutardialdehyde,Glutarol,Korsolex,Novaruca,Sekumatic,Sonacide,Sporicidin

Related Publications

A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
January 1977, The Journal of thoracic and cardiovascular surgery,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
June 1980, Cardiovascular diseases,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
February 1980, Artificial organs,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
August 1988, [Zasshi] [Journal]. Nihon Kyobu Geka Gakkai,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
January 1980, Catheterization and cardiovascular diagnosis,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
November 1980, The American journal of cardiology,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
January 1985, The Canadian journal of cardiology,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
October 1983, The Journal of thoracic and cardiovascular surgery,
A P Tandon, and D R Smith, and D A Mary, and M I Ionescu
June 1981, Cardiovascular diseases,
Copied contents to your clipboard!