Atrial flutter with exit block. 1979

C J Homcy, and B Lorell, and P M Yurchak

The mechanism of atrial flutter is controversial. A 76-year-old woman with rheumatic heart disease was referred to our clinic with an unusual rhythm disturbance which initially appeared to be classic atrial flutter at a rate of 300 beats/min. Later tracings, however, demonstrated a rate exactly one-half that of the earlier ECGs, with an identical p-wave morphology and vector. This latter rhythm also behaved in a manner expected for a flutter mechanism in that both spontaneously and with carotid pressure high-degree atrioventricular block occurred without alteration of the underlying atrial mechanism. Finally, the two rates interchanged spontaneously over several days without any significant interval changes in medical therapy. These findings were initially explained as probable digoxin toxicity. The underlying mechanism, however, was more likely atrial flutter with exit block and in this patient may have represented another facet of her sick sinus syndrome. This unusual phenomenon is discussed in terms of previous reports and possible implications for the mechanism of atrial flutter.

UI MeSH Term Description Entries
D008946 Mitral Valve Stenosis Narrowing of the passage through the MITRAL VALVE due to FIBROSIS, and CALCINOSIS in the leaflets and chordal areas. This elevates the left atrial pressure which, in turn, raises pulmonary venous and capillary pressure leading to bouts of DYSPNEA and TACHYCARDIA during physical exertion. RHEUMATIC FEVER is its primary cause. Mitral Stenosis,Mitral Stenoses,Mitral Valve Stenoses,Stenoses, Mitral,Stenoses, Mitral Valve,Stenosis, Mitral,Stenosis, Mitral Valve,Valve Stenoses, Mitral,Valve Stenosis, Mitral
D004077 Digoxin A cardiotonic glycoside obtained mainly from Digitalis lanata; it consists of three sugars and the aglycone DIGOXIGENIN. Digoxin has positive inotropic and negative chronotropic activity. It is used to control ventricular rate in ATRIAL FIBRILLATION and in the management of congestive heart failure with atrial fibrillation. Its use in congestive heart failure and sinus rhythm is less certain. The margin between toxic and therapeutic doses is small. (From Martindale, The Extra Pharmacopoeia, 30th ed, p666) Digacin,Digitek,Digoregen,Digoxina Boehringer,Digoxine Nativelle,Dilanacin,Hemigoxine Nativelle,Lanacordin,Lanicor,Lanoxicaps,Lanoxin,Lanoxin-PG,Lenoxin,Mapluxin,Boehringer, Digoxina,Lanoxin PG,Nativelle, Digoxine,Nativelle, Hemigoxine
D005260 Female Females
D006327 Heart Block Impaired conduction of cardiac impulse that can occur anywhere along the conduction pathway, such as between the SINOATRIAL NODE and the right atrium (SA block) or between atria and ventricles (AV block). Heart blocks can be classified by the duration, frequency, or completeness of conduction block. Reversibility depends on the degree of structural or functional defects. Auriculo-Ventricular Dissociation,A-V Dissociation,Atrioventricular Dissociation,A V Dissociation,A-V Dissociations,Atrioventricular Dissociations,Auriculo Ventricular Dissociation,Auriculo-Ventricular Dissociations,Block, Heart,Blocks, Heart,Dissociation, A-V,Dissociation, Atrioventricular,Dissociation, Auriculo-Ventricular,Dissociations, A-V,Dissociations, Atrioventricular,Dissociations, Auriculo-Ventricular,Heart Blocks
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D001022 Aortic Valve Insufficiency Pathological condition characterized by the backflow of blood from the ASCENDING AORTA back into the LEFT VENTRICLE, leading to regurgitation. It is caused by diseases of the AORTIC VALVE or its surrounding tissue (aortic root). Aortic Incompetence,Aortic Regurgitation,Aortic Valve Incompetence,Regurgitation, Aortic Valve,Incompetence, Aortic,Incompetence, Aortic Valve,Insufficiency, Aortic Valve,Regurgitation, Aortic
D001282 Atrial Flutter Rapid, irregular atrial contractions caused by a block of electrical impulse conduction in the right atrium and a reentrant wave front traveling up the inter-atrial septum and down the right atrial free wall or vice versa. Unlike ATRIAL FIBRILLATION which is caused by abnormal impulse generation, typical atrial flutter is caused by abnormal impulse conduction. As in atrial fibrillation, patients with atrial flutter cannot effectively pump blood into the lower chambers of the heart (HEART VENTRICLES). Auricular Flutter,Atrial Flutters,Auricular Flutters,Flutter, Atrial,Flutter, Auricular,Flutters, Atrial,Flutters, Auricular

Related Publications

C J Homcy, and B Lorell, and P M Yurchak
August 1969, Circulation,
C J Homcy, and B Lorell, and P M Yurchak
June 1988, Arquivos brasileiros de cardiologia,
C J Homcy, and B Lorell, and P M Yurchak
February 1946, Hospital (Rio de Janeiro, Brazil),
C J Homcy, and B Lorell, and P M Yurchak
January 1988, Arquivos brasileiros de cardiologia,
C J Homcy, and B Lorell, and P M Yurchak
January 1971, Journal of electrocardiology,
C J Homcy, and B Lorell, and P M Yurchak
November 1966, Circulation,
C J Homcy, and B Lorell, and P M Yurchak
September 1961, The Journal of the Indiana State Medical Association,
C J Homcy, and B Lorell, and P M Yurchak
November 1960, British heart journal,
C J Homcy, and B Lorell, and P M Yurchak
October 1963, The American journal of cardiology,
Copied contents to your clipboard!