Human rotavirus detection by counterimmunoelectrophoresis versus enzyme immunoassay and electron microscopy after direct ultracentrifugation. 1984

G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton

The sensitivity of the counterimmunoelectrophoresis test with NCDV, Wa, and SA-11 rotavirus antisera was 60, 60, and 67%, respectively. The counterimmunoelectrophoresis specificity was greater than 99%, but the low sensitivity is a limiting feature of this test as a first-line immunodiagnostic test for rotavirus detection.

UI MeSH Term Description Entries
D007122 Immunoelectrophoresis A technique that combines protein electrophoresis and double immunodiffusion. In this procedure proteins are first separated by gel electrophoresis (usually agarose), then made visible by immunodiffusion of specific antibodies. A distinct elliptical precipitin arc results for each protein detectable by the antisera.
D007124 Immunoenzyme Techniques Immunologic techniques based on the use of: (1) enzyme-antibody conjugates; (2) enzyme-antigen conjugates; (3) antienzyme antibody followed by its homologous enzyme; or (4) enzyme-antienzyme complexes. These are used histologically for visualizing or labeling tissue specimens. Antibody Enzyme Technique, Unlabeled,Enzyme Immunoassay,Enzyme-Labeled Antibody Technique,Immunoassay, Enzyme,Immunoperoxidase Techniques,Peroxidase-Antiperoxidase Complex Technique,Peroxidase-Labeled Antibody Technique,Antibody Enzyme Technic, Unlabeled,Enzyme-Labeled Antibody Technic,Immunoenzyme Technics,Immunoperoxidase Technics,Peroxidase-Antiperoxidase Complex Technic,Peroxidase-Labeled Antibody Technic,Antibody Technic, Enzyme-Labeled,Antibody Technic, Peroxidase-Labeled,Antibody Technics, Enzyme-Labeled,Antibody Technics, Peroxidase-Labeled,Antibody Technique, Enzyme-Labeled,Antibody Technique, Peroxidase-Labeled,Antibody Techniques, Enzyme-Labeled,Antibody Techniques, Peroxidase-Labeled,Enzyme Immunoassays,Enzyme Labeled Antibody Technic,Enzyme Labeled Antibody Technique,Enzyme-Labeled Antibody Technics,Enzyme-Labeled Antibody Techniques,Immunoassays, Enzyme,Immunoenzyme Technic,Immunoenzyme Technique,Immunoperoxidase Technic,Immunoperoxidase Technique,Peroxidase Antiperoxidase Complex Technic,Peroxidase Antiperoxidase Complex Technique,Peroxidase Labeled Antibody Technic,Peroxidase Labeled Antibody Technique,Peroxidase-Antiperoxidase Complex Technics,Peroxidase-Antiperoxidase Complex Techniques,Peroxidase-Labeled Antibody Technics,Peroxidase-Labeled Antibody Techniques,Technic, Enzyme-Labeled Antibody,Technic, Immunoenzyme,Technic, Immunoperoxidase,Technic, Peroxidase-Antiperoxidase Complex,Technic, Peroxidase-Labeled Antibody,Technics, Enzyme-Labeled Antibody,Technics, Immunoenzyme,Technics, Immunoperoxidase,Technics, Peroxidase-Antiperoxidase Complex,Technics, Peroxidase-Labeled Antibody,Technique, Enzyme-Labeled Antibody,Technique, Immunoenzyme,Technique, Immunoperoxidase,Technique, Peroxidase-Antiperoxidase Complex,Technique, Peroxidase-Labeled Antibody,Techniques, Enzyme-Labeled Antibody,Techniques, Immunoenzyme,Techniques, Immunoperoxidase,Techniques, Peroxidase-Antiperoxidase Complex,Techniques, Peroxidase-Labeled Antibody
D008854 Microscopy, Electron Microscopy using an electron beam, instead of light, to visualize the sample, thereby allowing much greater magnification. The interactions of ELECTRONS with specimens are used to provide information about the fine structure of that specimen. In TRANSMISSION ELECTRON MICROSCOPY the reactions of the electrons that are transmitted through the specimen are imaged. In SCANNING ELECTRON MICROSCOPY an electron beam falls at a non-normal angle on the specimen and the image is derived from the reactions occurring above the plane of the specimen. Electron Microscopy
D003378 Counterimmunoelectrophoresis Immunoelectrophoresis in which immunoprecipitation occurs when antigen at the cathode is caused to migrate in an electric field through a suitable medium of diffusion against a stream of antibody migrating from the anode as a result of endosmotic flow. Electrosyneresis,Immunoelectroosmophoresis,Immunoelectrophoresis, Countercurrent,Immunoelectrophoresis, Crossover,Countercurrent Immunoelectrophoresis,Crossover Immunoelectrophoresis
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012401 Rotavirus A genus of REOVIRIDAE, causing acute gastroenteritis in BIRDS and MAMMALS, including humans. Transmission is horizontal and by environmental contamination. Seven species (Rotaviruses A thru G) are recognized. Neonatal Calf Diarrhea Virus,Rotaviruses
D014461 Ultracentrifugation Centrifugation with a centrifuge that develops centrifugal fields of more than 100,000 times gravity. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed)

Related Publications

G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
September 1981, Journal of virological methods,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
January 1985, Pathology,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
January 1985, Scandinavian journal of infectious diseases,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
February 1985, European journal of clinical microbiology,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
June 1990, Journal of clinical microbiology,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
April 1986, Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
March 1980, Mycopathologia,
G W Hammond, and G S Ahluwalia, and B Klisko, and P R Hazelton
September 1982, Journal of clinical microbiology,
Copied contents to your clipboard!