Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe. 1983

J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret

There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r = 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008944 Mitral Valve Insufficiency Backflow of blood from the LEFT VENTRICLE into the LEFT ATRIUM due to imperfect closure of the MITRAL VALVE. This can lead to mitral valve regurgitation. Mitral Incompetence,Mitral Regurgitation,Mitral Valve Incompetence,Mitral Insufficiency,Mitral Valve Regurgitation,Incompetence, Mitral,Incompetence, Mitral Valve,Insufficiency, Mitral,Insufficiency, Mitral Valve,Regurgitation, Mitral,Regurgitation, Mitral Valve,Valve Incompetence, Mitral,Valve Insufficiency, Mitral,Valve Regurgitation, Mitral
D008946 Mitral Valve Stenosis Narrowing of the passage through the MITRAL VALVE due to FIBROSIS, and CALCINOSIS in the leaflets and chordal areas. This elevates the left atrial pressure which, in turn, raises pulmonary venous and capillary pressure leading to bouts of DYSPNEA and TACHYCARDIA during physical exertion. RHEUMATIC FEVER is its primary cause. Mitral Stenosis,Mitral Stenoses,Mitral Valve Stenoses,Stenoses, Mitral,Stenoses, Mitral Valve,Stenosis, Mitral,Stenosis, Mitral Valve,Valve Stenoses, Mitral,Valve Stenosis, Mitral
D011877 Radionuclide Imaging The production of an image obtained by cameras that detect the radioactive emissions of an injected radionuclide as it has distributed differentially throughout tissues in the body. The image obtained from a moving detector is called a scan, while the image obtained from a stationary camera device is called a scintiphotograph. Gamma Camera Imaging,Radioisotope Scanning,Scanning, Radioisotope,Scintigraphy,Scintiphotography,Imaging, Gamma Camera,Imaging, Radionuclide
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D003936 Diagnosis, Computer-Assisted Application of computer programs designed to assist the physician in solving a diagnostic problem. Computer-Assisted Diagnosis,Computer Assisted Diagnosis,Computer-Assisted Diagnoses,Diagnoses, Computer-Assisted,Diagnosis, Computer Assisted
D005260 Female Females
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006352 Heart Ventricles The lower right and left chambers of the heart. The right ventricle pumps venous BLOOD into the LUNGS and the left ventricle pumps oxygenated blood into the systemic arterial circulation. Cardiac Ventricle,Cardiac Ventricles,Heart Ventricle,Left Ventricle,Right Ventricle,Left Ventricles,Right Ventricles,Ventricle, Cardiac,Ventricle, Heart,Ventricle, Left,Ventricle, Right,Ventricles, Cardiac,Ventricles, Heart,Ventricles, Left,Ventricles, Right

Related Publications

J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
January 1983, European journal of nuclear medicine,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
January 1981, Circulation,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
November 1999, Heart (British Cardiac Society),
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
July 2000, Heart (British Cardiac Society),
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
January 1988, International journal of cardiac imaging,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
October 2004, The American journal of cardiology,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
February 1972, British heart journal,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
November 1995, Journal of the American College of Cardiology,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
March 2021, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology,
J Schneider, and H J Berger, and M J Sands, and A B Lachman, and B L Zaret
July 1985, International journal of cardiology,
Copied contents to your clipboard!