Simulated ECT of the left ventricle using rotating slant-hole collimator and two camera positions. 1984

K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes

Limited-angular-range tomography leads to an elongating distortion of the object in the direction of the z axis (perpendicular to the camera face). Two-view tomography appends to the usual data set another set of projections taken after the camera is rotated 90 degrees about an axis perpendicular to z. We investigated two-view tomography using a rotating-slant-hole collimator, 12 projections per view and the SMART iterative algorithm. Computer simulations extended previous results to include noise and attenuation. Phantoms imaged were the Au-rings in air and a ventricle phantom angled with respect to the z axis and placed in a water bath. Two-view results were generally superior compared to one-view results, were subject to some artifact in imaging defects, but could detect defects by looking at the differences between two sets of images, and were fairly insensitive to ventricle angulation. Therefore, two-view tomography has promise for thallium-type imaging.

UI MeSH Term Description Entries
D008961 Models, Structural A representation, generally small in scale, to show the structure, construction, or appearance of something. (From Random House Unabridged Dictionary, 2d ed) Model, Structural,Structural Model,Structural Models
D011868 Radioisotopes Isotopes that exhibit radioactivity and undergo radioactive decay. (From Grant & Hackh's Chemical Dictionary, 5th ed & McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Daughter Isotope,Daughter Nuclide,Radioactive Isotope,Radioactive Isotopes,Radiogenic Isotope,Radioisotope,Radionuclide,Radionuclides,Daughter Nuclides,Daugter Isotopes,Radiogenic Isotopes,Isotope, Daughter,Isotope, Radioactive,Isotope, Radiogenic,Isotopes, Daugter,Isotopes, Radioactive,Isotopes, Radiogenic,Nuclide, Daughter,Nuclides, Daughter
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006352 Heart Ventricles The lower right and left chambers of the heart. The right ventricle pumps venous BLOOD into the LUNGS and the left ventricle pumps oxygenated blood into the systemic arterial circulation. Cardiac Ventricle,Cardiac Ventricles,Heart Ventricle,Left Ventricle,Right Ventricle,Left Ventricles,Right Ventricles,Ventricle, Cardiac,Ventricle, Heart,Ventricle, Left,Ventricle, Right,Ventricles, Cardiac,Ventricles, Heart,Ventricles, Left,Ventricles, Right
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013793 Thallium A heavy, bluish white metal, atomic number 81, atomic weight [204.382; 204.385], symbol Tl. Thallium-205,Thallium 205
D014055 Tomography, Emission-Computed Tomography using radioactive emissions from injected RADIONUCLIDES and computer ALGORITHMS to reconstruct an image. CAT Scan, Radionuclide,CT Scan, Radionuclide,Computerized Emission Tomography,Radionuclide Tomography, Computed,Scintigraphy, Computed Tomographic,Tomography, Radionuclide-Computed,Computed Tomographic Scintigraphy,Emission-Computed Tomography,Radionuclide Computer-Assisted Tomography,Radionuclide Computerized Tomography,Radionuclide-Computed Tomography,Radionuclide-Emission Computed Tomography,Tomography, Computerized Emission,CAT Scans, Radionuclide,CT Scans, Radionuclide,Computed Radionuclide Tomography,Computed Tomography, Radionuclide-Emission,Computer-Assisted Tomographies, Radionuclide,Computer-Assisted Tomography, Radionuclide,Computerized Tomography, Radionuclide,Emission Computed Tomography,Emission Tomography, Computerized,Radionuclide CAT Scan,Radionuclide CAT Scans,Radionuclide CT Scan,Radionuclide CT Scans,Radionuclide Computed Tomography,Radionuclide Computer Assisted Tomography,Radionuclide Computer-Assisted Tomographies,Radionuclide Emission Computed Tomography,Scan, Radionuclide CAT,Scan, Radionuclide CT,Scans, Radionuclide CAT,Scans, Radionuclide CT,Tomographic Scintigraphy, Computed,Tomographies, Radionuclide Computer-Assisted,Tomography, Computed Radionuclide,Tomography, Emission Computed,Tomography, Radionuclide Computed,Tomography, Radionuclide Computer-Assisted,Tomography, Radionuclide Computerized,Tomography, Radionuclide-Emission Computed

Related Publications

K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
January 1984, Radioisotopes,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
April 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
May 1983, Physics in medicine and biology,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
April 2010, Medical physics,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
October 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
August 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
January 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
June 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
K F Koral, and C Nolder, and G Ciliax, and W L Rogers, and J W Keyes
July 2007, IEEE transactions on medical imaging,
Copied contents to your clipboard!