[Prosthesis endocarditis with embolization of a Smeloff-Cutter aortic valve prosthesis. Diagnosis, surgical management, clinical and hemodynamic course to 3 years' postoperative follow-up]. 1983

D Horstkotte, and R Körfer

In a 47-year-old man a late postoperative chronic infective prosthetic valve endocarditis became evident 8 years after implantation of a Smeloff-Cutter aortic valve prosthesis. Signs and symptoms of valve endocarditis increased rapidly, so that within 12 months a total valve embolization was found intraoperatively. Three years after emergency reoperation and implantation of a Björk-Shiley prosthesis, good clinical and hemodynamic results were established. Thus, even in prosthesis valve endocarditis with severe consecutive hemodynamic impairment, immediate surgical treatment seems to be mandatory and can be performed successfully with good long-term results if the diagnosis is made in time and if effective antimicrobial therapy is begun.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004617 Embolism Blocking of a blood vessel by an embolus which can be a blood clot or other undissolved material in the blood stream. Embolus,Embolisms
D004697 Endocarditis, Bacterial Inflammation of the ENDOCARDIUM caused by BACTERIA that entered the bloodstream. The strains of bacteria vary with predisposing factors, such as CONGENITAL HEART DEFECTS; HEART VALVE DISEASES; HEART VALVE PROSTHESIS IMPLANTATION; or intravenous drug use. Bacterial Endocarditides,Bacterial Endocarditis,Endocarditides, Bacterial
D006333 Heart Failure A heterogeneous condition in which the heart is unable to pump out sufficient blood to meet the metabolic need of the body. Heart failure can be caused by structural defects, functional abnormalities (VENTRICULAR DYSFUNCTION), or a sudden overload beyond its capacity. Chronic heart failure is more common than acute heart failure which results from sudden insult to cardiac function, such as MYOCARDIAL INFARCTION. Cardiac Failure,Heart Decompensation,Congestive Heart Failure,Heart Failure, Congestive,Heart Failure, Left-Sided,Heart Failure, Right-Sided,Left-Sided Heart Failure,Myocardial Failure,Right-Sided Heart Failure,Decompensation, Heart,Heart Failure, Left Sided,Heart Failure, Right Sided,Left Sided Heart Failure,Right Sided Heart Failure
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart

Related Publications

D Horstkotte, and R Körfer
January 1983, The Journal of cardiovascular surgery,
D Horstkotte, and R Körfer
October 1996, The Thoracic and cardiovascular surgeon,
D Horstkotte, and R Körfer
September 1977, The American journal of cardiology,
D Horstkotte, and R Körfer
April 2011, Asian cardiovascular & thoracic annals,
D Horstkotte, and R Körfer
November 1981, Archives des maladies du coeur et des vaisseaux,
D Horstkotte, and R Körfer
April 1983, Archives des maladies du coeur et des vaisseaux,
D Horstkotte, and R Körfer
November 1980, The Annals of thoracic surgery,
D Horstkotte, and R Körfer
February 1980, The Australian and New Zealand journal of surgery,
D Horstkotte, and R Körfer
May 2003, The Annals of thoracic surgery,
D Horstkotte, and R Körfer
July 1997, Zeitschrift fur Kardiologie,
Copied contents to your clipboard!