A comparison of incremental exercise tests during cycle and treadmill ergometry. 1983

R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson

We evaluated a short-duration maximum exercise test by comparing a 15-s incremental exercise protocol with a 1-min incremental method. Twenty normal men and women were studied using cycle and/or treadmill ergometry. In subjects tested on both exercise devices, anaerobic threshold and maximal oxygen uptake (VO2max) were higher for both protocols on the treadmill than on the cycle ergometer (P less than 0.001). However, when the 15-s and 1-min tests were compared using the same device (treadmill or cycle), there were no significant differences between protocols in anaerobic threshold or maximum exercise values of minute ventilation, respiratory rate, tidal volume, VO2max, oxygen pulse, and peak expiratory flow rate. Linear regression analyses indicated differences between the 15-s and 1-min protocols when cardiopulmonary measurements were related to power; however, the two protocols were comparable when cardiopulmonary data were related to oxygen uptake. Comparisons between protocols or between exercise devices were not systematically different in large vs small individuals, or in men vs women. Short-duration incremental exercise tests appear to be reliable, practical methods for assessing exercise performance in normal individuals.

UI MeSH Term Description Entries
D008297 Male Males
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D010366 Peak Expiratory Flow Rate Measurement of the maximum rate of airflow attained during a FORCED VITAL CAPACITY determination. Common abbreviations are PEFR and PFR. Expiratory Peak Flow Rate,Flow Rate, Peak Expiratory,PEFR
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D005541 Forced Expiratory Volume Measure of the maximum amount of air that can be expelled in a given number of seconds during a FORCED VITAL CAPACITY determination . It is usually given as FEV followed by a subscript indicating the number of seconds over which the measurement is made, although it is sometimes given as a percentage of forced vital capacity. Forced Vital Capacity, Timed,Timed Vital Capacity,Vital Capacity, Timed,FEVt,Capacities, Timed Vital,Capacity, Timed Vital,Expiratory Volume, Forced,Expiratory Volumes, Forced,Forced Expiratory Volumes,Timed Vital Capacities,Vital Capacities, Timed,Volume, Forced Expiratory,Volumes, Forced Expiratory
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014797 Vital Capacity The volume of air that is exhaled by a maximal expiration following a maximal inspiration. Forced Vital Capacity,Capacities, Forced Vital,Capacities, Vital,Capacity, Forced Vital,Capacity, Vital,Forced Vital Capacities,Vital Capacities,Vital Capacities, Forced,Vital Capacity, Forced

Related Publications

R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
January 2023, International journal of exercise science,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
September 2009, Clinical physiology and functional imaging,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
January 1997, European journal of applied physiology and occupational physiology,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
June 1992, The American review of respiratory disease,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
September 2010, Muscle & nerve,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
December 2004, Journal of sports science & medicine,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
November 2008, Respirology (Carlton, Vic.),
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
September 2000, Journal of applied physiology (Bethesda, Md. : 1985),
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
December 2020, Medicine and science in sports and exercise,
R D Fairshter, and J Walters, and K Salness, and M Fox, and V D Minh, and A F Wilson
November 1989, The American review of respiratory disease,
Copied contents to your clipboard!