Intercomparison of seven radioimmunoassay kits and a fluorescence polarization immunoassay kit for digoxin. 1984

K A Erickson, and P J Green

Samples from 33 patients being treated with digoxin and three concentrations of control material were analyzed for this drug by use of seven radioimmunoassay (RIA) kits and an automated fluorescence polarization immunoassay (FPIA) system. CVs ranged from 2.4 to 6.4% for the FPIA system and from 4.6 to 7.4% for two RIA methods. In the analysis of between-method variability of RIA kits, CVs ranged from 6.1 to 33.2%. We compared each RIA kit with the other six RIA kits (I), as well as each RIA kit with the FPIA system (II). Correlation coefficients were greater than or equal to 0.96 in all cases. Slopes ranged from 0.82 to 1.20 for comparison I and from 0.86 to 1.01 for comparison II. For the FPIA system, analytical recovery of digoxin ranged from 94 to 104%. For the RIA methods we examined, analytical recoveries ranged from 113 to 135%. Analysis time is shorter and precision is greater for the FPIA system than for the RIA methods.

UI MeSH Term Description Entries
D007118 Immunoassay A technique using antibodies for identifying or quantifying a substance. Usually the substance being studied serves as antigen both in antibody production and in measurement of antibody by the test substance. Immunochromatographic Assay,Assay, Immunochromatographic,Assays, Immunochromatographic,Immunoassays,Immunochromatographic Assays
D011863 Radioimmunoassay Classic quantitative assay for detection of antigen-antibody reactions using a radioactively labeled substance (radioligand) either directly or indirectly to measure the binding of the unlabeled substance to a specific antibody or other receptor system. Non-immunogenic substances (e.g., haptens) can be measured if coupled to larger carrier proteins (e.g., bovine gamma-globulin or human serum albumin) capable of inducing antibody formation. Radioimmunoassays
D011933 Reagent Kits, Diagnostic Commercially prepared reagent sets, with accessory devices, containing all of the major components and literature necessary to perform one or more designated diagnostic tests or procedures. They may be for laboratory or personal use. Diagnostic Reagent Kits,Diagnostic Reagents and Test Kits,Diagnostic Test Kits,In Vitro Diagnostic Device,In Vitro Diagnostic Devices,In Vitro Diagnostic Medical Device,In Vitro Diagnostic Medical Devices,Kits, Diagnostic Reagent,Diagnostic Reagent Kit,Diagnostic Test Kit,Kit, Diagnostic Reagent,Kit, Diagnostic Test,Kits, Diagnostic Test,Reagent Kit, Diagnostic,Test Kit, Diagnostic,Test Kits, Diagnostic
D004077 Digoxin A cardiotonic glycoside obtained mainly from Digitalis lanata; it consists of three sugars and the aglycone DIGOXIGENIN. Digoxin has positive inotropic and negative chronotropic activity. It is used to control ventricular rate in ATRIAL FIBRILLATION and in the management of congestive heart failure with atrial fibrillation. Its use in congestive heart failure and sinus rhythm is less certain. The margin between toxic and therapeutic doses is small. (From Martindale, The Extra Pharmacopoeia, 30th ed, p666) Digacin,Digitek,Digoregen,Digoxina Boehringer,Digoxine Nativelle,Dilanacin,Hemigoxine Nativelle,Lanacordin,Lanicor,Lanoxicaps,Lanoxin,Lanoxin-PG,Lenoxin,Mapluxin,Boehringer, Digoxina,Lanoxin PG,Nativelle, Digoxine,Nativelle, Hemigoxine
D005454 Fluorescence Polarization Measurement of the polarization of fluorescent light from solutions or microscopic specimens. It is used to provide information concerning molecular size, shape, and conformation, molecular anisotropy, electronic energy transfer, molecular interaction, including dye and coenzyme binding, and the antigen-antibody reaction. Anisotropy, Fluorescence,Fluorescence Anisotropy,Polarization, Fluorescence,Anisotropies, Fluorescence,Fluorescence Anisotropies,Fluorescence Polarizations,Polarizations, Fluorescence
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

K A Erickson, and P J Green
April 1987, Drug intelligence & clinical pharmacy,
K A Erickson, and P J Green
August 1979, American journal of clinical pathology,
K A Erickson, and P J Green
September 1977, Clinical chemistry,
K A Erickson, and P J Green
February 1979, Clinical chemistry,
K A Erickson, and P J Green
January 1984, Therapeutic drug monitoring,
K A Erickson, and P J Green
January 1977, Horumon to rinsho. Clinical endocrinology,
Copied contents to your clipboard!