Detection of neonatal intracranial hemorrhage utilizing real-time and static ultrasound. 1981

M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti

Accurate assessment of neonatal brain anatomy and pathology can now be obtained with commercially available ultrasound equipment. Intracranial hemorrhage (ICH) has a 50% to 60% incidence in premature infants under 32 wk gestational age and is felt to be one of the leading causes of neonatal morbidity and mortality. Computerized tomography (CT) has been the standard for detecting ICH; this study demonstrates that ultrasound is equally accurate and sensitive. Real-time examination through the anterior fontanelle resulted in 100% accuracy when compared with CT in a prospective study. Compound axial scans through the parietal bone were not as accurate, with a sensitivity of 91% and a specificity of 85%. If available, good quality real-time, transfontanelle sector ultrasound should be the screening procedure of choice for detecting and following intracranial hemorrhage in the high-risk premature infant.

UI MeSH Term Description Entries
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D007232 Infant, Newborn, Diseases Diseases of newborn infants present at birth (congenital) or developing within the first month of birth. It does not include hereditary diseases not manifesting at birth or within the first 30 days of life nor does it include inborn errors of metabolism. Both HEREDITARY DISEASES and METABOLISM, INBORN ERRORS are available as general concepts. Neonatal Diseases,Disease, Neonatal,Diseases, Neonatal,Neonatal Disease
D007235 Infant, Premature, Diseases Diseases that occur in PREMATURE INFANTS.
D002543 Cerebral Hemorrhage Bleeding into one or both CEREBRAL HEMISPHERES including the BASAL GANGLIA and the CEREBRAL CORTEX. It is often associated with HYPERTENSION and CRANIOCEREBRAL TRAUMA. Brain Hemorrhage, Cerebral,Cerebral Parenchymal Hemorrhage,Hemorrhage, Cerebral,Intracerebral Hemorrhage,Hemorrhage, Cerebrum,Brain Hemorrhages, Cerebral,Cerebral Brain Hemorrhage,Cerebral Brain Hemorrhages,Cerebral Hemorrhages,Cerebral Parenchymal Hemorrhages,Cerebrum Hemorrhage,Cerebrum Hemorrhages,Hemorrhage, Cerebral Brain,Hemorrhage, Cerebral Parenchymal,Hemorrhage, Intracerebral,Hemorrhages, Cerebral,Hemorrhages, Cerebral Brain,Hemorrhages, Cerebral Parenchymal,Hemorrhages, Cerebrum,Hemorrhages, Intracerebral,Intracerebral Hemorrhages,Parenchymal Hemorrhage, Cerebral,Parenchymal Hemorrhages, Cerebral
D003951 Diagnostic Errors Incorrect or incomplete diagnoses following clinical or technical diagnostic procedures. Diagnostic Blind Spots,Errors, Diagnostic,Misdiagnosis,Blind Spot, Diagnostic,Blind Spots, Diagnostic,Diagnostic Blind Spot,Diagnostic Error,Error, Diagnostic,Misdiagnoses
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography
D014463 Ultrasonography The visualization of deep structures of the body by recording the reflections or echoes of ultrasonic pulses directed into the tissues. Use of ultrasound for imaging or diagnostic purposes employs frequencies ranging from 1.6 to 10 megahertz. Echography,Echotomography,Echotomography, Computer,Sonography, Medical,Tomography, Ultrasonic,Ultrasonic Diagnosis,Ultrasonic Imaging,Ultrasonographic Imaging,Computer Echotomography,Diagnosis, Ultrasonic,Diagnostic Ultrasound,Ultrasonic Tomography,Ultrasound Imaging,Diagnoses, Ultrasonic,Diagnostic Ultrasounds,Imaging, Ultrasonic,Imaging, Ultrasonographic,Imaging, Ultrasound,Imagings, Ultrasonographic,Imagings, Ultrasound,Medical Sonography,Ultrasonic Diagnoses,Ultrasonographic Imagings,Ultrasound, Diagnostic,Ultrasounds, Diagnostic

Related Publications

M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
February 1984, Radiology,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
August 1980, Journal of clinical ultrasound : JCU,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
April 1982, American journal of obstetrics and gynecology,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
February 1993, Indian pediatrics,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
August 2011, Interface focus,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
July 1981, The Journal of pediatrics,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
April 1981, American journal of diseases of children (1960),
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
March 1979, Obstetrics and gynecology,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
November 1988, Zhonghua fu chan ke za zhi,
M L Johnson, and C M Rumack, and E J Mannes, and K E Appareti
December 1979, Pediatrics,
Copied contents to your clipboard!