Medical radiation dosimetry. 1982

N Suntharalingam

Current dose measuring practices in the diagnostic and therapeutic use of radiation are reviewed. Radiation doses typically received by patients from diagnostic X-ray studies, including mammography and computerized axial tomography, are presented. Modern-day radiation therapy, both with conventional photons and with electrons and high-LET particles, emphasizes the need for accurate dosimetry. The different methods of beam calibration and dosimetry intercomparisons for the variety of radiation beams are discussed. Results of several important dosimetry intercomparisons are also presented.

UI MeSH Term Description Entries
D008327 Mammography Radiographic examination of the breast. 3D-Mammography,Digital Breast Tomosynthesis,Digital Mammography,X-ray Breast Tomosynthesis,3D Mammography,3D-Mammographies,Breast Tomosyntheses, Digital,Breast Tomosyntheses, X-ray,Breast Tomosynthesis, Digital,Breast Tomosynthesis, X-ray,Digital Breast Tomosyntheses,Digital Mammographies,Mammographies,Mammographies, Digital,Mammography, Digital,X ray Breast Tomosynthesis,X-ray Breast Tomosyntheses
D009502 Neutrons Electrically neutral elementary particles found in all atomic nuclei except light hydrogen; the mass is equal to that of the proton and electron combined and they are unstable when isolated from the nucleus, undergoing beta decay. Slow, thermal, epithermal, and fast neutrons refer to the energy levels with which the neutrons are ejected from heavier nuclei during their decay. Neutron
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011859 Radiography Examination of any part of the body for diagnostic purposes by means of X-RAYS or GAMMA RAYS, recording the image on a sensitized surface (such as photographic film). Radiology, Diagnostic X-Ray,Roentgenography,X-Ray, Diagnostic,Diagnostic X-Ray,Diagnostic X-Ray Radiology,X-Ray Radiology, Diagnostic,Diagnostic X Ray,Diagnostic X Ray Radiology,Diagnostic X-Rays,Radiology, Diagnostic X Ray,X Ray Radiology, Diagnostic,X Ray, Diagnostic,X-Rays, Diagnostic
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D011879 Radiotherapy Dosage The total amount of radiation absorbed by tissues as a result of radiotherapy. Dosage, Radiotherapy,Dosages, Radiotherapy,Radiotherapy Dosages
D011882 Radiotherapy, High-Energy Radiotherapy using high-energy (megavolt or higher) ionizing radiation. Types of radiation include gamma rays, produced by a radioisotope within a teletherapy unit; x-rays, electrons, protons, alpha particles (helium ions) and heavy charged ions, produced by particle acceleration; and neutrons and pi-mesons (pions), produced as secondary particles following bombardment of a target with a primary particle. Megavolt Radiotherapy,High-Energy Radiotherapy,Radiotherapy, Megavolt,High Energy Radiotherapy,Radiotherapy, High Energy
D004583 Electrons Stable elementary particles having the smallest known negative charge, present in all elements; also called negatrons. Positively charged electrons are called positrons. The numbers, energies and arrangement of electrons around atomic nuclei determine the chemical identities of elements. Beams of electrons are called CATHODE RAYS. Fast Electrons,Negatrons,Positrons,Electron,Electron, Fast,Electrons, Fast,Fast Electron,Negatron,Positron
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

N Suntharalingam
January 2008, Radiation protection dosimetry,
N Suntharalingam
July 1969, Annals of the New York Academy of Sciences,
N Suntharalingam
February 1991, Environmental health perspectives,
N Suntharalingam
August 1981, Science (New York, N.Y.),
N Suntharalingam
August 1981, Science (New York, N.Y.),
N Suntharalingam
January 2014, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
N Suntharalingam
May 2019, Sensors (Basel, Switzerland),
N Suntharalingam
December 1969, Aerospace medicine,
N Suntharalingam
December 1967, Environmental health series. RH, Radiological health,
N Suntharalingam
April 1967, Health physics,
Copied contents to your clipboard!