Ultrasonography of prosthetic cardiac valves. 1981

G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky

Although many cases of prosthetic valve malfunction have appeared in the literature, statistically significant reports of the noninvasive diagnosis of valve malfunction are few. Metal-and-plastic mitral valves may be evaluated by a combined echocardiographic and phonocardiographic approach. Analysis of the A2-MVO interval seems to provide the most amount of information; supportive data useful in identifying the cause of valve malfunction come from phonocardiographic murmur and echocardiographic wall motion analysis. Additional cases of valve dysfunction will be detected if spectral analysis and cinefluoroscopy are also used. Suspected cases of mitral prosthetic malfunction must always be differentiated from left ventricular dysfunction; this may require invasive study. There is no evidence that two-dimensional echocardiography has any use in the analysis of metal-and-plastic mitral valves. There is no evidence that any noninvasive technique, particularly echocardiography, can consistently detect metal-and-plastic aortic prosthesis malfunction, especially of the tilting-disc type of valve. Noninvasive evaluation of tissue heterograft valves in the mitral and aortic positions require combined M-mode and two-dimensional echocardiographic study. Morphologic and functional alteration in these valves can be detected. Most importantly, accurate analysis of any particular valve requires an understanding of the individual clinical setting.

UI MeSH Term Description Entries
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D010701 Phonocardiography Graphic registration of the heart sounds picked up as vibrations and transformed by a piezoelectric crystal microphone into a varying electrical output according to the stresses imposed by the sound waves. The electrical output is amplified by a stethograph amplifier and recorded by a device incorporated into the electrocardiograph or by a multichannel recording machine. Phonocardiographies
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001021 Aortic Valve The valve between the left ventricle and the ascending aorta which prevents backflow into the left ventricle. Aortic Valves,Valve, Aortic,Valves, Aortic
D001705 Bioprosthesis Prosthesis, usually heart valve, composed of biological material and whose durability depends upon the stability of the material after pretreatment, rather than regeneration by host cell ingrowth. Durability is achieved 1, mechanically by the interposition of a cloth, usually polytetrafluoroethylene, between the host and the graft, and 2, chemically by stabilization of the tissue by intermolecular linking, usually with glutaraldehyde, after removal of antigenic components, or the use of reconstituted and restructured biopolymers. Glutaraldehyde-Stabilized Grafts,Heterograft Bioprosthesis,Porcine Xenograft Bioprosthesis,Xenograft Bioprosthesis,Bioprostheses,Bioprostheses, Heterograft,Bioprostheses, Porcine Xenograft,Bioprostheses, Xenograft,Bioprosthesis, Heterograft,Bioprosthesis, Porcine Xenograft,Bioprosthesis, Xenograft,Glutaraldehyde Stabilized Grafts,Glutaraldehyde-Stabilized Graft,Graft, Glutaraldehyde-Stabilized,Grafts, Glutaraldehyde-Stabilized,Heterograft Bioprostheses,Porcine Xenograft Bioprostheses,Xenograft Bioprostheses,Xenograft Bioprostheses, Porcine,Xenograft Bioprosthesis, Porcine
D014183 Transplantation, Heterologous Transplantation between animals of different species. Xenotransplantation,Heterograft Transplantation,Heterografting,Heterologous Transplantation,Xenograft Transplantation,Xenografting,Transplantation, Heterograft,Transplantation, Xenograft

Related Publications

G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
January 1987, Progress in cardiovascular nursing,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
October 1983, Connecticut medicine,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
January 1988, The American journal of cardiovascular pathology,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
October 2003, Archives of internal medicine,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
May 1990, Cardiology clinics,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
May 1968, Circulation,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
October 1983, Archives of internal medicine,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
April 1967, Radiology,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
March 1967, California medicine,
G S Mintz, and M N Kotler, and R M Steiner, and P Walinsky
October 1973, Circulation,
Copied contents to your clipboard!