Application of scanning electron microscopy to x-ray analysis of frozen-hydrated sections. II. Analysis of standard solutions and artificial electrolyte gradients. 1981

A J Saubermann, and R Beeuwkes, and P D Peters

New specimen handling and analytic techniques for the application of x-ray microanalysis to studies of cell and organ biology have been recently described (Saubermann et al., 1981, J. Cell Biol. 88:257-267). Based on these techniques, absolute quantitative standardization has been established through x-ray analysis of frozen-hydrated and then dried sections of independently measured standard solutions of elements. These experiments demonstrate that the specific techniques employed have a probable error of less than 10%. Artificial electrolyte gradients established in gelatin were subjected to analysis to determine whether there was elemental displacement under non-membrane-limited conditions at the temperatures employed for sectioning (-30 degrees to -40 degrees C). No significant difference was observed between such gradients in serial sections cut at -30 degrees and -80 degrees C. Similarly, no additional ice-crystal-damage artifact was found in sections cut at -30 degrees C when compared with sections cut at -80 degrees C. Thus, in terms of ice-crystal size, gradient maintenance, and compartmental differentiation, cryosectioning at -30 degrees to -40 degrees C was not associated with redistribution incompatible with 1- to 2-micrometers spatial resolution, and absolute measurements of elemental concentration were practical within regions of this size.

UI MeSH Term Description Entries
D008855 Microscopy, Electron, Scanning Microscopy in which the object is examined directly by an electron beam scanning the specimen point-by-point. The image is constructed by detecting the products of specimen interactions that are projected above the plane of the sample, such as backscattered electrons. Although SCANNING TRANSMISSION ELECTRON MICROSCOPY also scans the specimen point by point with the electron beam, the image is constructed by detecting the electrons, or their interaction products that are transmitted through the sample plane, so that is a form of TRANSMISSION ELECTRON MICROSCOPY. Scanning Electron Microscopy,Electron Scanning Microscopy,Electron Microscopies, Scanning,Electron Microscopy, Scanning,Electron Scanning Microscopies,Microscopies, Electron Scanning,Microscopies, Scanning Electron,Microscopy, Electron Scanning,Microscopy, Scanning Electron,Scanning Electron Microscopies,Scanning Microscopies, Electron,Scanning Microscopy, Electron
D008867 Microtomy The technique of using a microtome to cut thin or ultrathin sections of tissues embedded in a supporting substance. The microtome is an instrument that hold a steel, glass or diamond knife in clamps at an angle to the blocks of prepared tissues, which it cuts in sections of equal thickness. Thin Sectioning,Ultramicrotomy,Sectioning, Thin,Sectionings, Thin,Thin Sectionings
D011188 Potassium An element in the alkali group of metals with an atomic symbol K, atomic number 19, and atomic weight 39.10. It is the chief cation in the intracellular fluid of muscle and other cells. Potassium ion is a strong electrolyte that plays a significant role in the regulation of fluid volume and maintenance of the WATER-ELECTROLYTE BALANCE.
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D002712 Chlorides Inorganic compounds derived from hydrochloric acid that contain the Cl- ion. Chloride,Chloride Ion Level,Ion Level, Chloride,Level, Chloride Ion
D003460 Crystallization The formation of crystalline substances from solutions or melts. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Crystalline Polymorphs,Polymorphism, Crystallization,Crystal Growth,Polymorphic Crystals,Crystal, Polymorphic,Crystalline Polymorph,Crystallization Polymorphism,Crystallization Polymorphisms,Crystals, Polymorphic,Growth, Crystal,Polymorph, Crystalline,Polymorphic Crystal,Polymorphisms, Crystallization,Polymorphs, Crystalline
D004573 Electrolytes Substances that dissociate into two or more ions, to some extent, in water. Solutions of electrolytes thus conduct an electric current and can be decomposed by it (ELECTROLYSIS). (Grant & Hackh's Chemical Dictionary, 5th ed) Electrolyte
D004577 Electron Probe Microanalysis Identification and measurement of ELEMENTS and their location based on the fact that X-RAYS emitted by an element excited by an electron beam have a wavelength characteristic of that element and an intensity related to its concentration. It is performed with an electron microscope fitted with an x-ray spectrometer, in scanning or transmission mode. Microscopy, Electron, X-Ray Microanalysis,Spectrometry, X-Ray Emission, Electron Microscopic,Spectrometry, X-Ray Emission, Electron Probe,X-Ray Emission Spectrometry, Electron Microscopic,X-Ray Emission Spectrometry, Electron Probe,X-Ray Microanalysis, Electron Microscopic,X-Ray Microanalysis, Electron Probe,Microanalysis, Electron Probe,Spectrometry, X Ray Emission, Electron Microscopic,Spectrometry, X Ray Emission, Electron Probe,X Ray Emission Spectrometry, Electron Microscopic,X Ray Emission Spectrometry, Electron Probe,X-Ray Microanalysis,Electron Probe Microanalyses,Microanalyses, Electron Probe,Microanalysis, X-Ray,Probe Microanalyses, Electron,Probe Microanalysis, Electron,X Ray Microanalysis,X Ray Microanalysis, Electron Microscopic,X Ray Microanalysis, Electron Probe
D005629 Frozen Sections Thinly cut sections of frozen tissue specimens prepared with a cryostat or freezing microtome. Frozen Section,Section, Frozen,Sections, Frozen
D013048 Specimen Handling Procedures for collecting, preserving, and transporting of specimens sufficiently stable to provide accurate and precise results suitable for clinical interpretation. Specimen Collection,Collection, Specimen,Collections, Specimen,Handling, Specimen,Handlings, Specimen,Specimen Collections,Specimen Handlings

Related Publications

A J Saubermann, and R Beeuwkes, and P D Peters
January 1981, Tissue & cell,
A J Saubermann, and R Beeuwkes, and P D Peters
January 1978, Microscopica acta. Supplement,
A J Saubermann, and R Beeuwkes, and P D Peters
March 2017, Scientific reports,
A J Saubermann, and R Beeuwkes, and P D Peters
November 1992, Journal of microscopy,
A J Saubermann, and R Beeuwkes, and P D Peters
January 2002, Journal of structural biology,
A J Saubermann, and R Beeuwkes, and P D Peters
May 1987, Journal of microscopy,
A J Saubermann, and R Beeuwkes, and P D Peters
March 1993, Scanning microscopy,
Copied contents to your clipboard!