Bayesian analysis of stress thallium-201 scintigraphy. 1981

R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie

The variation of the diagnostic value of stress Tl-201 scintigraphy with prevalence of coronary heart disease (CHD) in the population has been investigated using Bayesian reasoning. From scintigraphic and arteriographic data obtained in 100 consecutive patients presenting with chest pain, the sensitivity of stress Tl-201 scintigraphy for the detection of significant CHD was 90% and the specificity was 88%. From Bayes' Theorem, the posterior probability of having CHD for a given test result was calculated for prevalences of CHD ranging from 1% to 99%. The discriminant value of stress Tl-201 scintigraphy was best when the prevalence of CHD lay between 30% and 70% and maximum for a prevalence of 52%. Thus, stress Tl-201 scintigraphy would be an unsuitable diagnostic test where the prior probability of CHD is low, e.g., population screening programmes, and would add little where the clinical probability of having CHD is already high. However, where the prior probability of having CHD is intermediate stress Tl-201 scintigraphy may provide valuable diagnostic information.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011868 Radioisotopes Isotopes that exhibit radioactivity and undergo radioactive decay. (From Grant & Hackh's Chemical Dictionary, 5th ed & McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Daughter Isotope,Daughter Nuclide,Radioactive Isotope,Radioactive Isotopes,Radiogenic Isotope,Radioisotope,Radionuclide,Radionuclides,Daughter Nuclides,Daugter Isotopes,Radiogenic Isotopes,Isotope, Daughter,Isotope, Radioactive,Isotope, Radiogenic,Isotopes, Daugter,Isotopes, Radioactive,Isotopes, Radiogenic,Nuclide, Daughter,Nuclides, Daughter
D011877 Radionuclide Imaging The production of an image obtained by cameras that detect the radioactive emissions of an injected radionuclide as it has distributed differentially throughout tissues in the body. The image obtained from a moving detector is called a scan, while the image obtained from a stationary camera device is called a scintiphotograph. Gamma Camera Imaging,Radioisotope Scanning,Scanning, Radioisotope,Scintigraphy,Scintiphotography,Imaging, Gamma Camera,Imaging, Radionuclide
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D005082 Physical Exertion Expenditure of energy during PHYSICAL ACTIVITY. Intensity of exertion may be measured by rate of OXYGEN CONSUMPTION; HEAT produced, or HEART RATE. Perceived exertion, a psychological measure of exertion, is included. Physical Effort,Effort, Physical,Efforts, Physical,Exertion, Physical,Exertions, Physical,Physical Efforts,Physical Exertions
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001499 Bayes Theorem A theorem in probability theory named for Thomas Bayes (1702-1761). In epidemiology, it is used to obtain the probability of disease in a group of people with some characteristic on the basis of the overall rate of that disease and of the likelihood of that characteristic in healthy and diseased individuals. The most familiar application is in clinical decision analysis where it is used for estimating the probability of a particular diagnosis given the appearance of some symptoms or test result. Bayesian Analysis,Bayesian Estimation,Bayesian Forecast,Bayesian Method,Bayesian Prediction,Analysis, Bayesian,Bayesian Approach,Approach, Bayesian,Approachs, Bayesian,Bayesian Approachs,Estimation, Bayesian,Forecast, Bayesian,Method, Bayesian,Prediction, Bayesian,Theorem, Bayes
D013793 Thallium A heavy, bluish white metal, atomic number 81, atomic weight [204.382; 204.385], symbol Tl. Thallium-205,Thallium 205

Related Publications

R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
April 2003, Nihon rinsho. Japanese journal of clinical medicine,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
April 2003, Nihon rinsho. Japanese journal of clinical medicine,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
April 2003, Nihon rinsho. Japanese journal of clinical medicine,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
January 2007, Journal of cardiology,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
April 1991, The American journal of cardiology,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
July 1980, The Western journal of medicine,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
March 1979, Japanese circulation journal,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
May 1982, ZFA. Zeitschrift fur Allgemeinmedizin,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
January 1985, American heart journal,
R G Murray, and J H McKillop, and R G Bessent, and I Hutton, and A R Lorimer, and T D Lawrie
February 1984, International journal of cardiology,
Copied contents to your clipboard!