An animal model for testing automatic defibrillators. 1980

J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes

A promising therapy for ventricular fibrillation--a life-threatening cardiac arrhythmia--is implantation of an automatic defibrillator. A critical component of such a device is the system that detects the presence of ventricular fibrillation. Automatic systems for detecting ventricular fibrillation have been tested with arrhythmias produced by electric shocks in normal canine hearts, but have not been tested with spontaneous arrhythmias in hyperirritable hearts. We have developed an animal model to create arrhythmias without electrical stimulation and have used it to test our automatic defibrillator. This model permits evaluation of both reliability to diagnose VF and reliability to reject other tachyarrhythmias.

UI MeSH Term Description Entries
D008297 Male Males
D004285 Dogs The domestic dog, Canis familiaris, comprising about 400 breeds, of the carnivore family CANIDAE. They are worldwide in distribution and live in association with people. (Walker's Mammals of the World, 5th ed, p1065) Canis familiaris,Dog
D004554 Electric Countershock An electrical current applied to the HEART to terminate a CARDIAC ARRHYTHMIA. Cardiac Electroversion,Cardioversion,Defibrillation, Electric,Electroversion, Cardiac,Electrical Cardioversion,Electroversion Therapy,Therapy, Electroversion,Cardiac Electroversions,Cardioversion, Electrical,Cardioversions,Cardioversions, Electrical,Countershock, Electric,Countershocks, Electric,Defibrillations, Electric,Electric Countershocks,Electric Defibrillation,Electric Defibrillations,Electrical Cardioversions,Electroversion Therapies,Electroversions, Cardiac,Therapies, Electroversion
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005260 Female Females
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D001331 Automation Controlled operation of an apparatus, process, or system by mechanical or electronic devices that take the place of human organs of observation, effort, and decision. (From Webster's Collegiate Dictionary, 1993) Automations
D001698 Biomedical Engineering Application of principles and practices of engineering science to biomedical research and health care. Clinical Engineering,Engineering, Clinical,Engineering, Biomedical

Related Publications

J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
January 2007, Meditsinskaia tekhnika,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
May 1988, Lancet (London, England),
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
January 1994, Archives des maladies du coeur et des vaisseaux,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
December 1987, Journal of the American College of Cardiology,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
January 1994, Yao xue xue bao = Acta pharmaceutica Sinica,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
August 1988, British journal of hospital medicine,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
December 1989, Annals of emergency medicine,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
January 2003, Soins; la revue de reference infirmiere,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
March 1988, Journal of the American College of Cardiology,
J D Bourland, and C F Babbs, and W A Tacker, and L A Geddes
January 2006, Soins; la revue de reference infirmiere,
Copied contents to your clipboard!