Metabolic and ventilatory responses to submaximal and maximal exercise using different breathing assemblies. 1995

B W Evans, and J A Potteiger
Department of Physical Education, Indiana State University, Terre Haute 47809, USA.

This study compared ventilatory and metabolic responses during exercise using three breathing assemblies: mouthpiece/noseclip (BV); mouth/face mask (MM); and facemask (FM). Ten male runners completed three maximal treadmill tests with breathing assembly randomly assigned. Metabolic and ventilatory data were recorded every 15s, and heart rate (HR) and rating of perceived exertion (RPE) each min. No significant differences were found for treadmill run time, HRmax, respiratory exchange ratio (RER), and RPE, indicating similar efforts on all trials. No significant differences were found at maximal exercise for VO2 minute ventilation (VE), tidal volume (VT), and breathing frequency (f). At ventilatory threshold (TVENT), VO2, VE, and f were not significantly different. However, peak flow (PF) was significantly higher for BV than FM, and VT was significantly higher for BV than MM and FM. Results indicate alterations in ventilatory mechanics occur at TVENT, but type of breathing assembly does not significantly affect maximal values.

UI MeSH Term Description Entries
D008297 Male Males
D008397 Masks Devices that cover the nose and mouth to maintain aseptic conditions often for the prevention of the spread of infections (e.g. COVID19) or to administer inhaled anesthetics or other gases. Mask
D009064 Mouth Protectors Devices or pieces of equipment placed in or around the mouth or attached to instruments to protect the external or internal tissues of the mouth and the teeth. Mouth Guards,Mouthpieces, Protective,Mouth Pieces, Protective,Guard, Mouth,Guards, Mouth,Mouth Guard,Mouth Piece, Protective,Mouth Protector,Mouthpiece, Protective,Piece, Protective Mouth,Pieces, Protective Mouth,Protective Mouth Piece,Protective Mouth Pieces,Protective Mouthpiece,Protective Mouthpieces,Protector, Mouth,Protectors, Mouth
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D010465 Perception The process by which the nature and meaning of sensory stimuli are recognized and interpreted. Sensory Processing,Processing, Sensory
D012119 Respiration The act of breathing with the LUNGS, consisting of INHALATION, or the taking into the lungs of the ambient air, and of EXHALATION, or the expelling of the modified air which contains more CARBON DIOXIDE than the air taken in (Blakiston's Gould Medical Dictionary, 4th ed.). This does not include tissue respiration ( Breathing
D012123 Pulmonary Ventilation The total volume of gas inspired or expired per unit of time, usually measured in liters per minute. Respiratory Airflow,Ventilation Tests,Ventilation, Pulmonary,Expiratory Airflow,Airflow, Expiratory,Airflow, Respiratory,Test, Ventilation,Tests, Ventilation,Ventilation Test
D004734 Energy Metabolism The chemical reactions involved in the production and utilization of various forms of energy in cells. Bioenergetics,Energy Expenditure,Bioenergetic,Energy Expenditures,Energy Metabolisms,Expenditure, Energy,Expenditures, Energy,Metabolism, Energy,Metabolisms, Energy
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005082 Physical Exertion Expenditure of energy during PHYSICAL ACTIVITY. Intensity of exertion may be measured by rate of OXYGEN CONSUMPTION; HEAT produced, or HEART RATE. Perceived exertion, a psychological measure of exertion, is included. Physical Effort,Effort, Physical,Efforts, Physical,Exertion, Physical,Exertions, Physical,Physical Efforts,Physical Exertions

Related Publications

B W Evans, and J A Potteiger
January 2000, Revista da Associacao Medica Brasileira (1992),
B W Evans, and J A Potteiger
November 1987, International journal of sports medicine,
B W Evans, and J A Potteiger
December 1995, British journal of sports medicine,
B W Evans, and J A Potteiger
July 1987, Journal of applied physiology (Bethesda, Md. : 1985),
B W Evans, and J A Potteiger
January 1978, Medicine and science in sports,
B W Evans, and J A Potteiger
August 1983, Journal of applied physiology: respiratory, environmental and exercise physiology,
B W Evans, and J A Potteiger
January 1977, Annals of the New York Academy of Sciences,
B W Evans, and J A Potteiger
December 1972, Acta physiologica Scandinavica,
Copied contents to your clipboard!