Can measurements of potential doubling time (Tpot) be compared between laboratories? A quality control study. 1995

K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
Department of Radiotherapy, University Hospital, Leuven, Belgium.

The purpose of this study was to investigate the reproducibility of potential doubling time measurements of human tumors in different laboratories and to distinguish which steps in the measurement procedure were subject to the greatest variation. This was achieved by comparing measurements on the same source material in two different laboratories in which three aspects of the technique were separately studied, namely, preparation and staining of the nuclear suspensions, running the samples on the flow cytometer (FCM), and analyzing the two-parameter FCM data. This involved exchange between the two centers of fixed tumor material, stained nuclear suspensions, and FCM data on floppy disks. The analysis step was found to be the least variable step. For DNA synthesis time, Ts, and the labeling index, LI, the coefficients of determination (R2) ranged from 92% to 95.4%. A small systematic bias was observed, with one center measuring approximately 15% higher values for both LI and Ts. Different criteria for window placements were found to be a contributing factor. Variations in the FCM step were approximately equal to those for analysis, with no systematic deviations. Variations for the preparation and staining step were the largest (R2 = 60.5% and 38.1% for LI and Ts, respectively). However, this step was the only one subject to intratumoral variability, which was the largest contributing factor to the variations observed. In addition, however, LI was on average 41% higher in one center compared to the other, resulting in a systematic bias. Differences in the level of green fluorescence of the labeled cells implicated antibody differences as a possible cause. The variations found here for the three procedural aspects were significantly smaller than variations observed between tumors, a requirement for a predictive assay. Suggestions for implementation of quality control procedures include objective (computer-assisted) data analysis on two-parameter histograms and optimization of antibody combinations.

UI MeSH Term Description Entries
D007753 Laboratories Facilities equipped to carry out investigative procedures. Laboratory
D011786 Quality Control A system for verifying and maintaining a desired level of quality in a product or process by careful planning, use of proper equipment, continued inspection, and corrective action as required. (Random House Unabridged Dictionary, 2d ed) Control, Quality,Controls, Quality,Quality Controls
D002294 Carcinoma, Squamous Cell A carcinoma derived from stratified SQUAMOUS EPITHELIAL CELLS. It may also occur in sites where glandular or columnar epithelium is normally present. (From Stedman, 25th ed) Carcinoma, Epidermoid,Carcinoma, Planocellular,Carcinoma, Squamous,Squamous Cell Carcinoma,Carcinomas, Epidermoid,Carcinomas, Planocellular,Carcinomas, Squamous,Carcinomas, Squamous Cell,Epidermoid Carcinoma,Epidermoid Carcinomas,Planocellular Carcinoma,Planocellular Carcinomas,Squamous Carcinoma,Squamous Carcinomas,Squamous Cell Carcinomas
D002455 Cell Division The fission of a CELL. It includes CYTOKINESIS, when the CYTOPLASM of a cell is divided, and CELL NUCLEUS DIVISION. M Phase,Cell Division Phase,Cell Divisions,Division Phase, Cell,Division, Cell,Divisions, Cell,M Phases,Phase, Cell Division,Phase, M,Phases, M
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013194 Staining and Labeling The marking of biological material with a dye or other reagent for the purpose of identifying and quantitating components of tissues, cells or their extracts. Histological Labeling,Staining,Histological Labelings,Labeling and Staining,Labeling, Histological,Labelings, Histological,Stainings
D014407 Tumor Cells, Cultured Cells grown in vitro from neoplastic tissue. If they can be established as a TUMOR CELL LINE, they can be propagated in cell culture indefinitely. Cultured Tumor Cells,Neoplastic Cells, Cultured,Cultured Neoplastic Cells,Cell, Cultured Neoplastic,Cell, Cultured Tumor,Cells, Cultured Neoplastic,Cells, Cultured Tumor,Cultured Neoplastic Cell,Cultured Tumor Cell,Neoplastic Cell, Cultured,Tumor Cell, Cultured
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
October 1995, Cytometry,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
January 1995, Bulletin du cancer,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
June 1998, Veterinary research communications,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
February 1995, International journal of radiation oncology, biology, physics,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
February 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
November 1997, Zhonghua zhong liu za zhi [Chinese journal of oncology],
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
September 1993, British journal of cancer,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
October 1996, Bulletin du cancer,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
February 1998, International journal of oncology,
K Haustermans, and I Hofland, and G Pottie, and M Ramaekers, and A C Begg
February 1995, International journal of radiation oncology, biology, physics,
Copied contents to your clipboard!