Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities. 1995

C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
Department of Anesthesiology, Durham Veterans Affairs Medical Center, NC, USA.

A continuous, noninvasive device for blood pressure measurement using pulse transit time has been recently introduced. We compared blood pressure measurement determined using this device with simultaneous invasive blood pressure measurements in 35 patients undergoing general endotracheal anesthesia. Data were analyzed for accuracy and tracking ability of the noninvasive technique, and for frequency of unavailable pressure measurements by each method. A total of 25,133 measurements of systolic pressure, diastolic pressure, and mean arterial pressure (MAP) by each method were collected for comparison from 35 patients. Accuracy was expressed by reporting mean bias (invasive pressure minus noninvasive pressure) and limits of agreement between the two measurements. After correction for the offset found when measuring invasive and oscillometric methods of arterial pressure measurement, the mean biases for systolic, diastolic, and mean pressures by the pulse wave method were -0.37 mm Hg, -0.01 mm Hg, and -0.05 mm Hg, respectively (p < 0.001). The limits of agreement were: -29.0 to 28.2 mm Hg, -14.9 to 14.8 mm Hg, and -19.1 to 19.0 mm Hg, respectively (95% confidence intervals). When blood pressure measured invasively changed over time by more than 10 mm Hg, the noninvasive technique accurately tracked the direction of change 67% of the time. During the entire study, 3.2% of the invasive measurements were unavailable and 12.9% of the noninvasive measurements were unavailable. The continuous noninvasive monitoring technique is not of sufficient accuracy to replace direct invasive measurement of arterial blood pressure, owing to relatively wide limits of agreement between the two methods.(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D001795 Blood Pressure Determination Techniques used for measuring BLOOD PRESSURE. Blood Pressure Determinations,Determination, Blood Pressure
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015924 Blood Pressure Monitors Devices for continuously measuring and displaying the arterial blood pressure. Monitors, Blood Pressure,Sphygmomanometers, Continuous,Blood Pressure Monitor,Continuous Sphygmomanometer,Continuous Sphygmomanometers,Monitor, Blood Pressure,Pressure Monitor, Blood,Pressure Monitors, Blood,Sphygmomanometer, Continuous
D016343 Monitoring, Intraoperative The constant checking on the state or condition of a patient during the course of a surgical operation (e.g., checking of vital signs). Intraoperative Monitoring

Related Publications

C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
November 1991, [Hokkaido igaku zasshi] The Hokkaido journal of medical science,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
February 1992, Journal of cardiothoracic and vascular anesthesia,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
May 2012, Anesthesiology,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
February 1991, Der Anaesthesist,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
June 2019, Blood pressure monitoring,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
October 1992, Journal of cardiothoracic and vascular anesthesia,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
January 2024, Journal of intensive care medicine,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
January 2005, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
August 1991, Anesthesiology,
C C Young, and J B Mark, and W White, and A DeBree, and J S Vender, and A Fleming
April 1998, Critical care nurse,
Copied contents to your clipboard!