[The potentials of digital image-intensifier radiography exemplified by digital spot imaging (DSI)]. 1995

J Rückforth, and B Wein, and A Stargardt, and R W Günther
Klinik für Radiologische Diagnostik, RWTH Aachen.

OBJECTIVE We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. METHODS Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. RESULTS The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen technique. CONCLUSIONS The DSI system was well integrated in the daily routine of gastrointestinal examinations. Low dose imaging, direct availability of images and dynamic studies with a frame rate up to 8 images per second are the advantages of the DSI. The lower spatial resolution in some cases is a diagnostic disadvantage that can reduce the diagnostic information.

UI MeSH Term Description Entries
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D003287 Contrast Media Substances used to allow enhanced visualization of tissues. Radiopaque Media,Contrast Agent,Contrast Agents,Contrast Material,Contrast Materials,Radiocontrast Agent,Radiocontrast Agents,Radiocontrast Media,Agent, Contrast,Agent, Radiocontrast,Agents, Contrast,Agents, Radiocontrast,Material, Contrast,Materials, Contrast,Media, Contrast,Media, Radiocontrast,Media, Radiopaque
D004064 Digestive System A group of organs stretching from the MOUTH to the ANUS, serving to breakdown foods, assimilate nutrients, and eliminate waste. In humans, the digestive system includes the GASTROINTESTINAL TRACT and the accessory glands (LIVER; BILIARY TRACT; PANCREAS). Ailmentary System,Alimentary System
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D014963 X-Ray Intensifying Screens Screens which absorb the energy in the x-ray beam that has penetrated the patient and convert this energy into a light pattern which has as nearly as possible the same information as the original x-ray beam. The more light a screen produces for a given input of x-radiation, the less x-ray exposure and thus shorter exposure time are needed to expose the film. In most film-screen systems, the film is sandwiched between two screens in a cassette so that the emulsion on each side is exposed to the light from its contiguous screen. Film-Screen Systems, X-Ray,Radiographic Intensifying Screens,Screen-Film Systems, X-Ray,X-Ray Film-Screen Systems,Screens, Radiographic Intensifying,Xray Intensifying Screens,Film Screen Systems, X Ray,Film-Screen System, X-Ray,Intensifying Screen, Radiographic,Intensifying Screen, X-Ray,Intensifying Screen, Xray,Intensifying Screens, Radiographic,Intensifying Screens, X-Ray,Intensifying Screens, Xray,Radiographic Intensifying Screen,Screen Film Systems, X Ray,Screen, Radiographic Intensifying,Screen, X-Ray Intensifying,Screen, Xray Intensifying,Screen-Film System, X-Ray,Screens, X-Ray Intensifying,Screens, Xray Intensifying,System, X-Ray Film-Screen,System, X-Ray Screen-Film,Systems, X-Ray Film-Screen,Systems, X-Ray Screen-Film,X Ray Film Screen Systems,X Ray Intensifying Screens,X-Ray Film-Screen System,X-Ray Intensifying Screen,X-Ray Screen-Film System,X-Ray Screen-Film Systems,Xray Intensifying Screen

Related Publications

J Rückforth, and B Wein, and A Stargardt, and R W Günther
November 1989, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
June 1986, Digitale Bilddiagnostik,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
September 1993, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
April 1997, AJR. American journal of roentgenology,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
January 1992, Aktuelle Radiologie,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
November 1993, Acta radiologica (Stockholm, Sweden : 1987),
J Rückforth, and B Wein, and A Stargardt, and R W Günther
September 1989, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
June 1989, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
J Rückforth, and B Wein, and A Stargardt, and R W Günther
August 1989, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
Copied contents to your clipboard!