Validation of a radiotelemetry system for continuous blood pressure and heart rate monitoring in dogs. 1995

A A Truett, and D B West
Pennington Biomedical Research Center, Louisiana State University, Baton Rouge, USA.

A blood pressure telemetry system with catheter placement in the femoral artery was evaluated over a 119-day period in eight mongrel dogs. Every 3 weeks, the pressures recorded by telemetry were compared with direct, simultaneously recorded blood pressures measured from a femoral artery catheter implanted on the contralateral side. One telemetry device failed within 1 week of implant and was replaced before the beginning of data collection. Continuous blood pressure measures were accurate for a minimum of 17 weeks in all eight dogs. Acute changes in blood pressure and heart rate were not evaluated. Validation by simultaneous recording with a physiological monitor indicated that there was no drift in the telemetry blood pressure or heart rate during the 17-week period. Heart rates recorded by telemetry and a physiological monitor were identical, as were mean arterial pressures. The systolic pressure measured by the physiological monitor was consistently higher than that measured by telemetry. This may have been due to differences in the compliance of the catheter material in the two systems. Two devices failed within approximately 6 months of implant, apparently because of exhaustion of the battery. These findings indicate that this telemetry device can be used for periods of up to 17 weeks without appreciable drift or attenuation of the blood pressure signal. The results also describe a validation procedure for monitoring the accuracy of the telemetry system over extended periods of use. We conclude that this telemetry device can be used for the long-term assessment of blood pressure and heart rate in the dog.

UI MeSH Term Description Entries
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D001795 Blood Pressure Determination Techniques used for measuring BLOOD PRESSURE. Blood Pressure Determinations,Determination, Blood Pressure
D004285 Dogs The domestic dog, Canis familiaris, comprising about 400 breeds, of the carnivore family CANIDAE. They are worldwide in distribution and live in association with people. (Walker's Mammals of the World, 5th ed, p1065) Canis familiaris,Dog
D005260 Female Females
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D013686 Telemetry Transmission of the readings of instruments to a remote location by means of wires, radio waves, or other means. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Telemetries
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015924 Blood Pressure Monitors Devices for continuously measuring and displaying the arterial blood pressure. Monitors, Blood Pressure,Sphygmomanometers, Continuous,Blood Pressure Monitor,Continuous Sphygmomanometer,Continuous Sphygmomanometers,Monitor, Blood Pressure,Pressure Monitor, Blood,Pressure Monitors, Blood,Sphygmomanometer, Continuous

Related Publications

A A Truett, and D B West
September 1992, Journal of pharmacological and toxicological methods,
A A Truett, and D B West
July 2001, Journal of gravitational physiology : a journal of the International Society for Gravitational Physiology,
A A Truett, and D B West
May 1970, Research quarterly,
A A Truett, and D B West
December 1970, The Medical journal of Australia,
A A Truett, and D B West
August 1979, The Australian & New Zealand journal of obstetrics & gynaecology,
A A Truett, and D B West
May 2000, Journal of applied physiology (Bethesda, Md. : 1985),
A A Truett, and D B West
January 1969, Malattie cardiovascolari,
A A Truett, and D B West
December 2019, European heart journal supplements : journal of the European Society of Cardiology,
Copied contents to your clipboard!