Intra-arterial and extra-arterial pH, PCO2 and PO2 monitors. 1995

B A Shapiro
Northwestern University Medical School, Chicago, Illinois, USA.

In vitro blood gas analysers inherently limit the frequency of serial blood gas measurements because of blood loss and cost. In vivo blood gas monitors eliminate an inherent cost and blood loss associated with measurement. Optode microsensing is a technology that can be readily adapted to in vivo measurement of pH, PCO2, and PO2. Optode-based intra-arterial devices that display continuous values have been developed that are practical for routine use but consistent performance remains a problem; an extra-arterial device that provides intermittent values has been shown to be consistent but is not yet available for routine use. The transfer of blood gas measurements from laboratory analysers to the combination of point-of-care analysers and monitors should have as profound an impact on acute respiratory care as did the introduction of laboratory-based blood gas analysers over 30 years ago. However, we must be sure these devices are reliable, consistent and cost beneficial in order to avoid widespread adoption of yet another technology that provides more data, more cost, and questionable patient benefit.

UI MeSH Term Description Entries
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D001784 Blood Gas Analysis Measurement of oxygen and carbon dioxide in the blood. Analysis, Blood Gas,Analyses, Blood Gas,Blood Gas Analyses,Gas Analyses, Blood,Gas Analysis, Blood
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D006863 Hydrogen-Ion Concentration The normality of a solution with respect to HYDROGEN ions; H+. It is related to acidity measurements in most cases by pH pH,Concentration, Hydrogen-Ion,Concentrations, Hydrogen-Ion,Hydrogen Ion Concentration,Hydrogen-Ion Concentrations

Related Publications

B A Shapiro
August 1986, American journal of obstetrics and gynecology,
B A Shapiro
October 1969, The Cornell veterinarian,
B A Shapiro
January 1972, Journal of applied physiology,
B A Shapiro
September 1961, Journal of applied physiology,
B A Shapiro
January 1969, Biomedical sciences instrumentation,
B A Shapiro
December 1969, The American journal of physiology,
B A Shapiro
January 1970, Acta tuberculosea et pneumologica Belgica,
B A Shapiro
December 2004, Nihon rinsho. Japanese journal of clinical medicine,
Copied contents to your clipboard!