Calibrating and testing tissue equivalent proportional counters with 37Ar. 1994

E Anachkova, and A M Kellerer, and H Roos
Strahlenbiologisches Institut, Universität München, Germany.

A method for testing and calibrating tissue equivalent proportional counters with 37Ar is described. 37Ar is produced by exposure of argon in its normal isotope composition to thermal neutrons. It is shown that--up to volume ratios of 0.01 of argon to the tissue equivalent gas--there is no appreciable effect of the argon admixture on the function of the proportional counter. Conventional calibration methods with characteristic x-rays or with alpha-particles require modifications of the detectors, and they test only small sub-volumes in the counters. In contrast, argon permits calibrations and tests of the resolution that are representative for the entire counter volume and that do not require changes in detector construction. The method is equally applicable to multi-element proportional counters; it is here exemplified by its application to a long cylindrical counter of simplified design that is part of such a multi-element configuration.

UI MeSH Term Description Entries
D011868 Radioisotopes Isotopes that exhibit radioactivity and undergo radioactive decay. (From Grant & Hackh's Chemical Dictionary, 5th ed & McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Daughter Isotope,Daughter Nuclide,Radioactive Isotope,Radioactive Isotopes,Radiogenic Isotope,Radioisotope,Radionuclide,Radionuclides,Daughter Nuclides,Daugter Isotopes,Radiogenic Isotopes,Isotope, Daughter,Isotope, Radioactive,Isotope, Radiogenic,Isotopes, Daugter,Isotopes, Radioactive,Isotopes, Radiogenic,Nuclide, Daughter,Nuclides, Daughter
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D001128 Argon A noble gas with the atomic symbol Ar, atomic number 18, and atomic weight 39.948. It is used in fluorescent tubes and wherever an inert atmosphere is desired and nitrogen cannot be used. Argon-40,Argon 40

Related Publications

E Anachkova, and A M Kellerer, and H Roos
December 1970, Health physics,
E Anachkova, and A M Kellerer, and H Roos
September 2001, Medical physics,
E Anachkova, and A M Kellerer, and H Roos
April 2002, Radiation research,
E Anachkova, and A M Kellerer, and H Roos
July 2009, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
E Anachkova, and A M Kellerer, and H Roos
May 2002, Physics in medicine and biology,
E Anachkova, and A M Kellerer, and H Roos
January 2002, Radiation protection dosimetry,
E Anachkova, and A M Kellerer, and H Roos
April 1998, Radiation research,
E Anachkova, and A M Kellerer, and H Roos
January 1963, Arhiv za higijenu rada i toksikologiju,
E Anachkova, and A M Kellerer, and H Roos
June 1950, Nucleonics,
Copied contents to your clipboard!