Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing. 1995

B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
II Medical Clinic, Johannes Gutenberg University, Mainz, Germany.

The importance of atrioventricular synchronous pacing compared with single-chamber rate-responsive pacing is still under discussion, especially for low-intensity workload representing daily life activities. We evaluated hemodynamics in single-lead VDD pacing versus VVIR pacing in 11 patients (8 men and 3 women, aged 58.6 +/- 13.8 years) with normal left ventricular function and a previously implanted single-lead VDDR pacemaker. A low-intensity steady-state treadmill test at 1 to 2.5 mph with a gradient of 2% to 4% was performed. Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardiac output was measured in steady-state conditions. The pacemaker was then reprogrammed to the VVI mode at a rate 5 to 10 beats above the maximal atrial tracking rate to simulate rate-matched VVIR pacing (VVIRm). After 5 additional minutes of steady-state exercise, cardiac output was measured again. The maximal atrial rate in the VDD mode was 119 +/- 19 beats/min versus a programmed rate of 129 +/- 18 beats/min in the VVIRm mode. VDD pacing resulted in a significantly higher cardiac output than VVIRm pacing (10.6 +/- 1.9 vs 9.2 +/- 1.4 L/min; p < 0.002), with a mean difference of 1.6 +/- 1.2 L/min between the 2 modes. In the VDD mode, stroke volume (90.7 +/- 20.1 vs 71.6 +/- 13.0 ml; p < 0.001) and maximal oxygen uptake (1,183 +/- 264 vs 1,076 +/- 289 ml/min, p < 0.01) were also higher than in VVIRm.(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D006327 Heart Block Impaired conduction of cardiac impulse that can occur anywhere along the conduction pathway, such as between the SINOATRIAL NODE and the right atrium (SA block) or between atria and ventricles (AV block). Heart blocks can be classified by the duration, frequency, or completeness of conduction block. Reversibility depends on the degree of structural or functional defects. Auriculo-Ventricular Dissociation,A-V Dissociation,Atrioventricular Dissociation,A V Dissociation,A-V Dissociations,Atrioventricular Dissociations,Auriculo Ventricular Dissociation,Auriculo-Ventricular Dissociations,Block, Heart,Blocks, Heart,Dissociation, A-V,Dissociation, Atrioventricular,Dissociation, Auriculo-Ventricular,Dissociations, A-V,Dissociations, Atrioventricular,Dissociations, Auriculo-Ventricular,Heart Blocks
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
June 1990, Pacing and clinical electrophysiology : PACE,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
December 1990, Pacing and clinical electrophysiology : PACE,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
November 1996, Pacing and clinical electrophysiology : PACE,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
January 2007, Cardiology,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
April 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
December 1990, Pacing and clinical electrophysiology : PACE,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
November 1991, Clinical cardiology,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
August 1997, Pacing and clinical electrophysiology : PACE,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
August 2021, Micromachines,
B Nowak, and T Voigtländer, and E Himmrich, and A Liebrich, and G Poschmann, and S Epperlein, and N Treese, and J Meyer
September 2006, Revista espanola de cardiologia,
Copied contents to your clipboard!