Exercise-related changes in aortic flow measured with spiral echo-planar MR velocity mapping. 1995

R H Mohiaddin, and P D Gatehouse, and D N Firmin
Magnetic Resonance Unit, Royal Brompton Hospital, London, England.

Spiral echo-planar magnetic resonance (MR) velocity mapping was used to measure exercise-related changes in flow in the descending thoracic aorta in 10 healthy volunteers. Flow was measured at rest and immediately after dynamic exercise, with a 0.5-T imager with a surface receiving coil and electrocardiographic triggering. Supine exercise was performed with a home-built pedaling apparatus. Spiral velocity mapping was performed in a transverse plane through the descending thoracic aorta with the subject at rest. The subject was then asked to perform maximum exercise, stop, and hold his breath during a four-heartbeat acquisition time. Eight cine frames with a temporal resolution of 50 msec were acquired through systole. Each image was acquired in 40 msec during spiral acquisition of k-space data, starting at the center, 6 msec after the excitation pulse. Reproducibility of the technique was established by repeating the flow measurement in four consecutive heartbeats. At rest, the heart rate (mean +/- standard deviation), mean aortic flow, peak aortic flow, and time to peak flow were 68 beats per minute +/- 6, 41 milliliters per beat +/- 8, 107 mL/sec +/- 20, and 175 msec +/- 25, respectively. After exercise, the heart rate and mean and peak aortic flow were significantly increased (P < .001), measuring 101 beats per minute +/- 12, 57 milliliters per beat +/- 11, and 158 mL/sec +/- 29, respectively, while the time to peak flow (115 msec +/- 32) was significantly reduced (P < .001). The four sets of values obtained for the first four consecutive heartbeats measured at rest were similar, as were those obtained for the first four heartbeats after exercise.

UI MeSH Term Description Entries
D008297 Male Males
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D001013 Aorta, Thoracic The portion of the descending aorta proceeding from the arch of the aorta and extending to the DIAPHRAGM, eventually connecting to the ABDOMINAL AORTA. Aorta, Ascending,Aorta, Descending,Aortic Arch,Aortic Root,Arch of the Aorta,Descending Aorta,Sinotubular Junction,Ascending Aorta,Thoracic Aorta,Aortic Roots,Arch, Aortic,Ascending Aortas,Junction, Sinotubular,Root, Aortic,Sinotubular Junctions
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

R H Mohiaddin, and P D Gatehouse, and D N Firmin
December 1989, Magnetic resonance in medicine,
R H Mohiaddin, and P D Gatehouse, and D N Firmin
April 1995, Magnetic resonance in medicine,
R H Mohiaddin, and P D Gatehouse, and D N Firmin
January 1995, Journal of magnetic resonance imaging : JMRI,
R H Mohiaddin, and P D Gatehouse, and D N Firmin
October 2019, Journal of magnetic resonance (San Diego, Calif. : 1997),
R H Mohiaddin, and P D Gatehouse, and D N Firmin
June 2010, Journal of magnetic resonance (San Diego, Calif. : 1997),
R H Mohiaddin, and P D Gatehouse, and D N Firmin
January 1993, Radiology,
R H Mohiaddin, and P D Gatehouse, and D N Firmin
December 2013, Magnetic resonance in medicine,
R H Mohiaddin, and P D Gatehouse, and D N Firmin
January 1993, Journal of applied physiology (Bethesda, Md. : 1985),
R H Mohiaddin, and P D Gatehouse, and D N Firmin
February 1996, Radiology,
R H Mohiaddin, and P D Gatehouse, and D N Firmin
September 1994, Radiology,
Copied contents to your clipboard!