[Evaluation of the hematologic autoanalyzer Coulter Maxm]. 1995

I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
Servicio de Análisis Clínicos, Hospital de Son Dureta, Palma de Mallorca.

OBJECTIVE To evaluate the performance of the Coulter MaxM autoanalyser, based on volume, cell conductivity and laser-beam dispersion, and to assess the automated leucocyte differential count (LDC). METHODS A total number of 2,016 blood samples drawn on tri-K EDTA as anticoagulant were studied. The following data were analysed: 1-Intra- and inter-assay inaccuracy, the findings being expressed as mean and variation coefficient (CV%). 2- Correlation with the results attained with other systems (Coulter STKS and Technicon H1); The Pearson's correlation coefficient was used for this analysis. 3- Assessment of the morphologic suspect warning flags, optic microscope examination being used as reference. 4- Stability of the samples along time; the samples were analysed at 2, 6, 24 and 48 hours after withdrawal, and the Scheffe's test was used for comparison of results. 5- Performance speed. RESULTS 1- The intra-assay inaccuracy was found acceptable for all the values except the basophil count (CV: 30.8%). The lack of reproducibility for basophil count is similar to that observed in the Coulter STKS system. 2- Correlation: Optimal LDC was found for neutrophils, eosinophils and lymphocytes. Excellent correlation with the Coulter STKS was seen except for haemoglobin, haematocrit and basophil count. The correlation with the Technicon H1 was better then with the STKS, except for basophil and monocyte counts. The correlation with basophil count was low with every system. 3- Warning flags appeared in 13.4% of the samples, the worse results corresponded to basophils, monocytes, stabs and atypical lymphocytes. 4- Samples stored at 4 degrees C for 24 hr had not significant variations in LDC. Those ones stored at 20-25 degrees C only showed significant variations after 24 hr in the monocyte count. 5- The working speed was 60 samples processed and printed in one hour. CONCLUSIONS The Coulter MaxM autoanalyser is a useful machine for laboratories and provides a 5-class LDC plus a sound screen for leucocyte morphologic anomalies.

UI MeSH Term Description Entries
D001772 Blood Cell Count The number of LEUKOCYTES and ERYTHROCYTES per unit volume in a sample of venous BLOOD. A complete blood count (CBC) also includes measurement of the HEMOGLOBIN; HEMATOCRIT; and ERYTHROCYTE INDICES. Blood Cell Number,Blood Count, Complete,Blood Cell Counts,Blood Cell Numbers,Blood Counts, Complete,Complete Blood Count,Complete Blood Counts,Count, Blood Cell,Count, Complete Blood,Counts, Blood Cell,Counts, Complete Blood,Number, Blood Cell,Numbers, Blood Cell
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001331 Automation Controlled operation of an apparatus, process, or system by mechanical or electronic devices that take the place of human organs of observation, effort, and decision. (From Webster's Collegiate Dictionary, 1993) Automations
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
April 1992, Sangre,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
October 1994, Nouvelle revue francaise d'hematologie,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
July 1994, American journal of clinical pathology,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
February 1997, Sangre,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
August 1992, American journal of clinical pathology,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
January 1992, Nouvelle revue francaise d'hematologie,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
October 1991, Sangre,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
May 1984, Medicina clinica,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
December 1996, Clinical chemistry,
I Llompart, and M Vila, and P Quetglas, and G Pérez, and E Fuentespina
January 1981, Meditsinskaia tekhnika,
Copied contents to your clipboard!