Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients--from bedside-type to wearable-type. 1994

M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
Department of Metabolic Medicine, Kumamoto University Medical School, Japan.

The artificial endocrine pancreas is a feedback control system regulating insulin delivery on a minute-by-minute basis according to the measured blood glucose levels. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus but also as an elegant research tool for investigating the pathophysiology of the disease. With significant advances in the development of a subcutaneous tissue glucose monitoring system, the wearable-type artificial endocrine pancreas has been applied to diabetic patients. With this system, perfect glycemic control can be obtained for longer periods in ambulatory diabetic patients. The trend in the development of the artificial endocrine pancreas is now directed to implantable devices. Much efforts have been conducted to realize these devices.

UI MeSH Term Description Entries
D007328 Insulin A 51-amino acid pancreatic hormone that plays a major role in the regulation of glucose metabolism, directly by suppressing endogenous glucose production (GLYCOGENOLYSIS; GLUCONEOGENESIS) and indirectly by suppressing GLUCAGON secretion and LIPOLYSIS. Native insulin is a globular protein comprised of a zinc-coordinated hexamer. Each insulin monomer containing two chains, A (21 residues) and B (30 residues), linked by two disulfide bonds. Insulin is used as a drug to control insulin-dependent diabetes mellitus (DIABETES MELLITUS, TYPE 1). Iletin,Insulin A Chain,Insulin B Chain,Insulin, Regular,Novolin,Sodium Insulin,Soluble Insulin,Chain, Insulin B,Insulin, Sodium,Insulin, Soluble,Regular Insulin
D007332 Insulin Infusion Systems Portable or implantable devices for infusion of insulin. Includes open-loop systems which may be patient-operated or controlled by a pre-set program and are designed for constant delivery of small quantities of insulin, increased during food ingestion, and closed-loop systems which deliver quantities of insulin automatically based on an electronic glucose sensor. Pancreas, Artificial Endocrine,Programmable Implantable Insulin Pump,beta Cell, Artificial,Implantable Programmable Insulin Pump,Insulin Pump, Programmable Implantable,Pump, Programmable Implantable Insulin,Artificial Endocrine Pancreas,Artificial beta Cell,Artificial beta Cells,Cell, Artificial beta,Cells, Artificial beta,Endocrine Pancreas, Artificial,Infusion System, Insulin,Infusion Systems, Insulin,Insulin Infusion System,System, Insulin Infusion,Systems, Insulin Infusion,beta Cells, Artificial
D007564 Japan A country in eastern Asia, island chain between the North Pacific Ocean and the Sea of Japan, east of the Korean Peninsula. The capital is Tokyo. Bonin Islands
D001786 Blood Glucose Glucose in blood. Blood Sugar,Glucose, Blood,Sugar, Blood
D003920 Diabetes Mellitus A heterogeneous group of disorders characterized by HYPERGLYCEMIA and GLUCOSE INTOLERANCE.
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015190 Blood Glucose Self-Monitoring Self evaluation of whole blood glucose levels outside the clinical laboratory. A digital or battery-operated reflectance meter may be used. It has wide application in controlling unstable insulin-dependent diabetes. Blood Sugar Self-Monitoring,Home Blood Glucose Monitoring,Monitoring, Home Blood Glucose,Self-Monitoring, Blood Glucose,Glucose, Blood, Self Monitoring,Glucose, Blood, Self-Monitoring,Blood Glucose Self Monitoring,Blood Glucose Self-Monitorings,Blood Sugar Self Monitoring,Blood Sugar Self-Monitorings,Glucose Self-Monitoring, Blood,Glucose Self-Monitorings, Blood,Self Monitoring, Blood Glucose,Self-Monitoring, Blood Sugar,Self-Monitorings, Blood Glucose,Self-Monitorings, Blood Sugar,Sugar Self-Monitoring, Blood,Sugar Self-Monitorings, Blood
D015918 Infusion Pumps, Implantable Implanted fluid propulsion systems with self-contained power source for providing long-term controlled-rate delivery of drugs such as chemotherapeutic agents or analgesics. Delivery rate may be externally controlled or osmotically or peristatically controlled with the aid of transcutaneous monitoring. Drug Delivery Systems, Implantable,Implantable Infusion Pumps,Perfusion Pumps, Implantable,Peristaltic Pumps, Implantable,Programmable Implantable Medication Systems,Implantable Medication Systems, Programmable,Medication Systems, Programmable Implantable,Systems, Programmable Implantable Medication,Implantable Infusion Pump,Implantable Perfusion Pump,Implantable Perfusion Pumps,Implantable Peristaltic Pump,Implantable Peristaltic Pumps,Infusion Pump, Implantable,Perfusion Pump, Implantable,Peristaltic Pump, Implantable,Pump, Implantable Infusion,Pump, Implantable Perfusion,Pump, Implantable Peristaltic,Pumps, Implantable Infusion,Pumps, Implantable Perfusion,Pumps, Implantable Peristaltic

Related Publications

M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
January 1987, Medical progress through technology,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
September 1984, Medical journal of Osaka University,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
November 1982, Lancet (London, England),
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
January 1979, Hormone and metabolic research. Supplement series,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
January 1983, Life support systems : the journal of the European Society for Artificial Organs,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
January 2006, Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
January 1998, Artificial organs,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
November 1988, The International journal of artificial organs,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
November 1997, Nihon rinsho. Japanese journal of clinical medicine,
M Shichiri, and H Kishikawa, and M Sakakida, and K Kajiwara, and Y Hashiguchi, and K Nishida, and T Uemura, and Y Konno, and K Ichinose
September 2002, Nihon rinsho. Japanese journal of clinical medicine,
Copied contents to your clipboard!