Immobilized buffers for isoelectric focusing: from gradient gels to membranes. 1994

P G Righetti, and E Giaffreda
Faculty of Pharmacy, University of Milano, Italy.

Some major improvements to a pH gradient simulator for isoelectric focusing in immobilized buffers are here described. They allow creation of graphs (giving the profiles of pH gradient, deviation from ideal shape, buffering power and ionic strength) with up to 200 increments (which, in a 1 pH unit span means mapping of pH intervals at barely 0.005 pH increments per step). In addition, for preparative purification protocols, utilizing multicompartment electrolyzers with isoelectric, buffering membranes, this modified program allows easy calculation of the precise pI value at any point along the pH gradient used for the analytical assessment of the pI values of the proteins to be purified. At the desired pH value, reached by moving the cursor along the pH gradient, a simple clicking of the mouse button allows the display of the instant Immobiline composition responsible for that pH value. The molarity ratio of the various Immobilines present at this precise point of the pH scale in fact gives the composition (with the accompanying value of buffering power and ionic strength) of the membrane to be utilized as a pH-stat in the preparative scale run. This is the only method that allows reproducible and valid scaling up from the analytical to the preparative scale.

UI MeSH Term Description Entries
D007202 Indicators and Reagents Substances used for the detection, identification, analysis, etc. of chemical, biological, or pathologic processes or conditions. Indicators are substances that change in physical appearance, e.g., color, at or approaching the endpoint of a chemical titration, e.g., on the passage between acidity and alkalinity. Reagents are substances used for the detection or determination of another substance by chemical or microscopical means, especially analysis. Types of reagents are precipitants, solvents, oxidizers, reducers, fluxes, and colorimetric reagents. (From Grant & Hackh's Chemical Dictionary, 5th ed, p301, p499) Indicator,Reagent,Reagents,Indicators,Reagents and Indicators
D007525 Isoelectric Focusing Electrophoresis in which a pH gradient is established in a gel medium and proteins migrate until they reach the site (or focus) at which the pH is equal to their isoelectric point. Electrofocusing,Focusing, Isoelectric
D008567 Membranes, Artificial Artificially produced membranes, such as semipermeable membranes used in artificial kidney dialysis (RENAL DIALYSIS), monomolecular and bimolecular membranes used as models to simulate biological CELL MEMBRANES. These membranes are also used in the process of GUIDED TISSUE REGENERATION. Artificial Membranes,Artificial Membrane,Membrane, Artificial
D009994 Osmolar Concentration The concentration of osmotically active particles in solution expressed in terms of osmoles of solute per liter of solution. Osmolality is expressed in terms of osmoles of solute per kilogram of solvent. Ionic Strength,Osmolality,Osmolarity,Concentration, Osmolar,Concentrations, Osmolar,Ionic Strengths,Osmolalities,Osmolar Concentrations,Osmolarities,Strength, Ionic,Strengths, Ionic
D002021 Buffers A chemical system that functions to control the levels of specific ions in solution. When the level of hydrogen ion in solution is controlled the system is called a pH buffer. Buffer
D003198 Computer Simulation Computer-based representation of physical systems and phenomena such as chemical processes. Computational Modeling,Computational Modelling,Computer Models,In silico Modeling,In silico Models,In silico Simulation,Models, Computer,Computerized Models,Computer Model,Computer Simulations,Computerized Model,In silico Model,Model, Computer,Model, Computerized,Model, In silico,Modeling, Computational,Modeling, In silico,Modelling, Computational,Simulation, Computer,Simulation, In silico,Simulations, Computer
D006863 Hydrogen-Ion Concentration The normality of a solution with respect to HYDROGEN ions; H+. It is related to acidity measurements in most cases by pH pH,Concentration, Hydrogen-Ion,Concentrations, Hydrogen-Ion,Hydrogen Ion Concentration,Hydrogen-Ion Concentrations
D012984 Software Sequential operating programs and data which instruct the functioning of a digital computer. Computer Programs,Computer Software,Open Source Software,Software Engineering,Software Tools,Computer Applications Software,Computer Programs and Programming,Computer Software Applications,Application, Computer Software,Applications Software, Computer,Applications Softwares, Computer,Applications, Computer Software,Computer Applications Softwares,Computer Program,Computer Software Application,Engineering, Software,Open Source Softwares,Program, Computer,Programs, Computer,Software Application, Computer,Software Applications, Computer,Software Tool,Software, Computer,Software, Computer Applications,Software, Open Source,Softwares, Computer Applications,Softwares, Open Source,Source Software, Open,Source Softwares, Open,Tool, Software,Tools, Software

Related Publications

P G Righetti, and E Giaffreda
August 1996, Electrophoresis,
P G Righetti, and E Giaffreda
January 1988, Methods in molecular biology (Clifton, N.J.),
P G Righetti, and E Giaffreda
November 1999, Analytical biochemistry,
P G Righetti, and E Giaffreda
February 1988, Electrophoresis,