Quantitative and 3-dimensional analysis of Langerhans' cells following occlusion with patch tests using confocal laser scanning microscopy. 1993

A Emilson, and M Lindberg, and B Forslind, and A Scheynius
Department of Clinical Immunology, Karolinska Hospital, Stockholm, Sweden.

Quantitative and detailed 3-dimensional (3-D) morphological information can be obtained from the same tissue volume using a confocal laser scanning microscope (CLSM). In the present study, we used CLSM for evaluation of Langerhans' cells (LC) in human skin at 0 h, 24 h and 48 h following occlusion with patch tests for 48 h. The relative volume of epidermal CD1a reactivity was quantified with CLSM on 25 microns thick sections stained with indirect immunofluorescence. No statistically significant difference was found when comparing the values obtained on the biopsy specimens from occluded skin (n = 36) with those from non-occluded skin (n = 9). Nor were any statistically significant changes detected in the number of epidermal CD1a+ cells as determined with immunoperoxidase staining between occluded and non-occluded skin. The occlusion produced a transient mild inflammatory reaction with an induced expression of intercellular adhesion molecule-1 (ICAM-1) on keratinocytes and an increased number of CD3+ epidermal lymphocytes. In addition, 3-D reconstructions revealed spatial information on the distribution of LC dendrites towards the skin surface.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D007801 Langerhans Cells Recirculating, dendritic, antigen-presenting cells containing characteristic racket-shaped granules (Birbeck granules). They are found principally in the stratum spinosum of the EPIDERMIS and are rich in Class II MAJOR HISTOCOMPATIBILITY COMPLEX molecules. Langerhans cells were the first dendritic cell to be described and have been a model of study for other dendritic cells (DCs), especially other migrating DCs such as dermal DCs and INTERSTITIAL DENDRITIC CELLS. Langerhans Cell,Dendritic Cells, Dermal,Dendritic Cells, Epidermal,Dendritic Cells, Skin,Dermal Dendritic Cells,Epidermal Dendritic Cells,Skin Dendritic Cells,Cell, Dermal Dendritic,Cell, Epidermal Dendritic,Cell, Langerhans,Cell, Skin Dendritic,Cells, Dermal Dendritic,Cells, Epidermal Dendritic,Cells, Langerhans,Cells, Skin Dendritic,Dendritic Cell, Dermal,Dendritic Cell, Epidermal,Dendritic Cell, Skin,Dermal Dendritic Cell,Epidermal Dendritic Cell,Skin Dendritic Cell
D007834 Lasers An optical source that emits photons in a coherent beam. Light Amplification by Stimulated Emission of Radiation (LASER) is brought about using devices that transform light of varying frequencies into a single intense, nearly nondivergent beam of monochromatic radiation. Lasers operate in the infrared, visible, ultraviolet, or X-ray regions of the spectrum. Masers,Continuous Wave Lasers,Pulsed Lasers,Q-Switched Lasers,Continuous Wave Laser,Laser,Laser, Continuous Wave,Laser, Pulsed,Laser, Q-Switched,Lasers, Continuous Wave,Lasers, Pulsed,Lasers, Q-Switched,Maser,Pulsed Laser,Q Switched Lasers,Q-Switched Laser
D008214 Lymphocytes White blood cells formed in the body's lymphoid tissue. The nucleus is round or ovoid with coarse, irregularly clumped chromatin while the cytoplasm is typically pale blue with azurophilic (if any) granules. Most lymphocytes can be classified as either T or B (with subpopulations of each), or NATURAL KILLER CELLS. Lymphoid Cells,Cell, Lymphoid,Cells, Lymphoid,Lymphocyte,Lymphoid Cell
D008297 Male Males
D008853 Microscopy The use of instrumentation and techniques for visualizing material and details that cannot be seen by the unaided eye. It is usually done by enlarging images, transmitted by light or electron beams, with optical or magnetic lenses that magnify the entire image field. With scanning microscopy, images are generated by collecting output from the specimen in a point-by-point fashion, on a magnified scale, as it is scanned by a narrow beam of light or electrons, a laser, a conductive probe, or a topographical probe. Compound Microscopy,Hand-Held Microscopy,Light Microscopy,Optical Microscopy,Simple Microscopy,Hand Held Microscopy,Microscopy, Compound,Microscopy, Hand-Held,Microscopy, Light,Microscopy, Optical,Microscopy, Simple
D009779 Occlusive Dressings Material, usually gauze or absorbent cotton, used to cover and protect wounds, to seal them from contact with air or bacteria. (From Dorland, 27th ed) Bandages, Occlusive,Dressings, Occlusive,Dressings, Spray-On,Bandage, Occlusive,Dressing, Occlusive,Dressing, Spray-On,Dressings, Spray On,Occlusive Bandage,Occlusive Bandages,Occlusive Dressing,Spray-On Dressing,Spray-On Dressings
D005260 Female Females
D005455 Fluorescent Antibody Technique Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy. Antinuclear Antibody Test, Fluorescent,Coon's Technique,Fluorescent Antinuclear Antibody Test,Fluorescent Protein Tracing,Immunofluorescence Technique,Coon's Technic,Fluorescent Antibody Technic,Immunofluorescence,Immunofluorescence Technic,Antibody Technic, Fluorescent,Antibody Technics, Fluorescent,Antibody Technique, Fluorescent,Antibody Techniques, Fluorescent,Coon Technic,Coon Technique,Coons Technic,Coons Technique,Fluorescent Antibody Technics,Fluorescent Antibody Techniques,Fluorescent Protein Tracings,Immunofluorescence Technics,Immunofluorescence Techniques,Protein Tracing, Fluorescent,Protein Tracings, Fluorescent,Technic, Coon's,Technic, Fluorescent Antibody,Technic, Immunofluorescence,Technics, Fluorescent Antibody,Technics, Immunofluorescence,Technique, Coon's,Technique, Fluorescent Antibody,Technique, Immunofluorescence,Techniques, Fluorescent Antibody,Techniques, Immunofluorescence,Tracing, Fluorescent Protein,Tracings, Fluorescent Protein
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

A Emilson, and M Lindberg, and B Forslind, and A Scheynius
January 1990, Archives of dermatological research,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
December 1994, The British journal of dermatology,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
September 1992, Acta dermato-venereologica,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
January 2001, Angiogenesis,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
June 2005, Analytical and quantitative cytology and histology,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
February 1985, Optics letters,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
June 2002, Toxicological sciences : an official journal of the Society of Toxicology,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
September 1998, Archives of oral biology,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
October 1990, Cell calcium,
A Emilson, and M Lindberg, and B Forslind, and A Scheynius
November 2003, Journal of microscopy,
Copied contents to your clipboard!